The wireless RVR-52 data logger monitors and records voltage, pulse and event. The logger
features wireless data transmission to a collector (Sold Separately) within 100 meters, battery life of 6 months with 1 lithium battery, alarm notifications, 15 sampling intervals and 16K of data storage.
The voltage logger can measure up to 30 counts (30Hz) per second when the input voltage range is between 0-30V and there is a continuous pulse of more than 15 milliseconds. When measuring pulse, the largest number of counts for one recording interval is 32,000 counts. You can select from rising signal (Lo to Hi) or falling signal (Hi to Lo) and count when one or the other occurs. Large Battery Option Available.
Required with Wireless Voltage Logger
>> Wireless Data Collector (#RTR-5W, #RTR-57U or #RTR-50)
Each Wireless Voltage Logger Includes
>> O-Ring, Screws and Silica Gel
>> User Manual
>> Battery
NOTE: Large Quantity Discounts available!
Wireless Voltage / Pulse Logger Features
- Single Channel Voltage, Pulse or Event Logger
- 15 Different Sampling Interval (1 second to 60 minutes)
- 6 Month Battery Life
- Audible Alarm when Low/High Thresholds are Met
- Excitation Voltage of 2.5 Volts with Maximum of 2 milliamps
- Wireless Commnications in -30°C to 80°C Range
- Large Capacity Battery Pack Available
- Requires Wireless Data Collector (#RTR-57U ), Wireless Communications Port (#RTR-50) or Wireless Network Station (# RTR-5W)
- Includes Software, Battery and User Manual
Wireless Voltage / Pulse Logger Specifications
Measurement Channel | 1 Voltage or 1 Pulse or 1 Event Voltage |
Standard Sensor | RPR-7101 Sensor with 1.5 Cable Length |
Input Voltage Range | Voltage: 0 to 6.5VDC Pulse: 0 to 30VDC Event: 0 to 30VDC |
Display Resolution | Voltage: 1mV Event: 1 sec |
Voltage Accuracy | ±0.5% ±5dgt (0°C to 40°C) |
Excitation Voltage | 2.5 Volts with a Maximum of 2 MilliAmps |
Detection Voltage | Low: below 0.6V High: above 2V |
Response Time | Pulse: 30Hz / Approx. 15msec or more (over 2.5V) Event: 1 second |
Response Polarity | Pulse: select Lo-Hi or Hi-Lo Event: Both Lo-Hi and Hi-Lo |
Input Impedance | Pull-up Resistor Approx.100kΩ |
Data Storage Capacity | Voltage or Pulse: 16,000 Readings Event: 8,000 Readings |
Highest No. of Pulse Counts | 32,000 Counts |
Recording Interval | 1, 2, 5, 10, 15, 20, 30 sec. / 1, 2, 5, 10, 15, 20, 30, 60 minutes (Total of 15 choices) |
Water Resistance | IP64 (Rated for Use in Daily Life) (Water protection is rated as Splashproof when the sensor is connected - Not for Continued Immersion) |
Recording Mode | Endless: Overwrite Oldest Data when Capacity is Full One-Time: Stop Recording When Capacity is Full |
LCD Display Items | Current Readings / Recording Settings / Battery Life Warning / Over Measurement Range Warning / Amount of Recorded Data |
Power | Lithium Battery (LS14250(SAFT)) or optional AC Adaptor |
Battery Life | RVR-52: Approx. 6 months RVR-52L: 2.5 Years (Battery life depends on measurement environment, recording interval and battery performance) |
Dimension | 62 mm x 47 mm x 19 mm (excluding protrusions / antenna length 20mm) |
Wireless Method | FCC Part 15 Section 249 / IC RSS-210 |
Communication Speed | When downloading data (Wireless) about 2,000 readings per minute [Collection of a full unit of data= about 420 seconds (optical communication = about 160 seconds)] |
Transmission Range | Up to 100 Meters (May Vary With Conditions) |
Temperature Resistance | -40°C to 80°C |
Description | Part Number | |||
TandD Wireless Voltage/Pulse Logger | RVR-52A | |||
TandD Voltage & Pulse - Large Battery Pack Version w/o Batteries | RVR-52AL | |||
TandD Voltage & Pulse - Large Battery Pack Version with Batteries | RVR-52AL-B | |||
Wireless Collector - 1 Required | ||||
TandD Wireless Data Collector w/ Software and USB Cable | RTR-57U | |||
TandD Wireless Data Collector with full Network Connectivity | RTR-5W | |||
Wireless Data Collector and Repeater | RTR-50 | |||
Optional Accessories | ||||
TandD 110 Volt AC Adapter | AD-0638 | |||
TandD 4-20 mA Probe | RVR-5203 | |||
Wall Mount for RTR-5 and RTR-500 Series Loggers | TR-05K3 | |||
Moisture Sensor Adapter Cable (Limited Quantity - 7 Available) | VR-2C10--U-- | |||
Moisture Sensor Adapter Cable | VR-2C10 | |||
Extra/Replacement 3.6V 1/2 AA Lithium Battery | HP-B | |||
TandD Large Capacity Battery Pack (w/o Battery) | RTR-05B1 | |||
TandD External Power Pack w/ 110V AC Adapter | RTR-05A1 | |||
Tadiran Lithium Battery, 3.6 Volts, C Cell | TL2200/S | |||
Wall Mount for RTR-5 and RTR-500 Series Loggers w/ Large Battery Pack | TR-05K3L | |||
Optional NIST Calibration | ||||
Standard NIST DC Voltage Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders | CAL-NIST-DCVOLT |
Large Battery Pack Option: The Large Battery Pack provides continuous use for up to 2.5 years. The battery will allow you to measure and record over long periods of time whether the unit is in transit or in a distant place.
Note: Battery life will depend on the recording environment, recording interval, communication frequensy, and ambient temperature. The above battery life test was carried out using brand new batteries and in no way do we guarantee a battery's life. Removing the battery and not replacing it will result in a loss of all recorded data.
Documentation:
TandD RTR-5 series of loggers User Manual (.pdf)
RTR-57 Data Collector Manual (.pdf)