Wireless Temperature Logger with Internal Sensor

 

The wireless temperature data logger with internal sensor can measure and record temperatures from -40 to +80°C. The logger features wireless data transmission to datacollector (Sold Separately) within 100 meters, battery life of 6 months with 1 lithium battery, Alarm notifications, 15 sampling intervals and 16K of data storage. Large Battery Option Available.

Required with Wireless Temperature Logger
>> Wireless Data Collector (#RTR-5W, #RTR-57U or #RTR-50)

Each Wireless Temperature Logger Includes
>> O-Ring, Screws and Silica Gel 
>> User Manual 
>> Battery

NOTE: NIST Calibration is available.
Large Quantity Discounts available!

Wireless Temperature Logger Features

  • Single Channel Wireless Temperature Data Recorder
  • 15 Different Sampling Interval (1 second to 60 minutes)
  • Monitor Environmental Conditons and Transmit Captured Data Wirelesssly
  • Audible Alarm when Low/High Thresholds are Met
  • Large Capacity Battery Pack Available
  • Requires Wireless Data Collector (#RTR-57U ) , Wireless Communications Port (#RTR-50) or Wireless Network Station (# RTR-5W)
  • Includes Software, Battery and User Manual

Wireless Temperature Logger Specifications

Measurement Channel 1 Internal Temperature Sensor
Temperature Sensor Range -40°C to +80°C
Measurement Display Resolution 0.1°C
Measurement Accuracy Avg. ±0.5°C
Data Storage Capacity 16,000 Samples
Recording Interval 1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes ( Total of 15 choices)
Water Resistance IP67 (Full Immersion)
Recording Mode Endless: Overwrite Oldest Data when Capacity is Full
One-time: Stop Recording when Capacity is Full
LCD Display Items Current Readings / Recording Settings / Battery Life Warning / Over Measurement Range Warning / Amount of Recorded Data
Power Lithium Battery (LS14250(SAFT)) or AC Adaptor (Sold Separately)
Battery Life RTR-51: Approx. 6 months 
RTR-51L: 2.5 Years 
(Battery life depends on measurement environment, recording interval and battery performance)
Dimension 62mm x 47mm x 19mm (excluding protrusions / antenna length 20mm)
Wireless Method FCC Part 15 Section 249 / IC RSS-210
Communication Speed When downloading data (Wireless) about 2,000 readings per minute [Collection of a full unit of data= about 420 seconds (optical communication= about 160 seconds)]
Transmission Distance Up to 100 meters (may vary with conditions)
Unit Temp. Resistance -40°C to 80°C


Description Part Number
TandD Wireless Temperature Logger with Internal Sensor RTR-51
TandD Wireless Temperature Logger - Large Battery Pack Version w/o Batteries RTR-51L
TandD Wireless Temperature Logger - Large Battery Pack Version includes Battery RTR-51L-B
Wireless Collector - 1 Required
TandD Wireless Data Collector w/ Software and USB Cable RTR-57U
Wireless Data Collector and Repeater RTR-50
TandD Wireless Data Collector with full Network Connectivity RTR-5W
Standard NIST Calibration Service
Standard NIST Temperature Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders CAL-NIST-TEMP
Optional Accessories
TandD 110 Volt AC Adapter AD-0638
CFR 21 Part 11 Secure Software (Limited Quantity - 1 Available) VLD-5-US--U--
CFR 21 Part 11 Secure Software VLD-5-US
Wall Mount for RTR-5 and RTR-500 Series Loggers TR-05K3
TandD Large Capacity Battery Pack (w/o Battery) RTR-05B1
Extra/Replacement 3.6V 1/2 AA Lithium Battery HP-B
TandD External Power Pack w/ 110V AC Adapter RTR-05A1
Tadiran Lithium Battery, 3.6 Volts, C Cell TL2200/S
Wall Mount for RTR-5 and RTR-500 Series Loggers w/ Large Battery Pack TR-05K3L

Large Battery Pack Option: The Large Battery Pack provides continuous use for up to 2.5 years. The battery will allow you to measure and record over long periods of time whether the unit is in transit or in a distant place.
Note: Battery life will depend on the recording environment, recording interval, communication frequensy, and ambient temperature. The above battery life test was carried out using brand new batteries and in no way do we guarantee a battery's life. Removing the battery and not replacing it will result in a loss of all recorded data.

Documentation: (pdf)

TandD RTR-5 series of loggers User Manual (.pdf)
RTR-57 Data Collector Manual (.pdf)