>> Stores up to 2 Million Recorded Readings
>> 0 to 3.0 Volt Measurement Range for Analog Inputs (Additional Ranges Available: 0 to 20mA, 4 to 20mA, 0.5V to 4.5V,0 to 5V, 1V to 6V, 0 to 10V, 0 to 12V and 0 to 24V by Special Order)
>> Each Analog Input Can Be Replaced with Internal or External Sensor
>> Internal Sensors Available for Temp, Humidity, Pressure & 3-Axis Acceleration
>> External Sensors Available for Temperature, Humidity & Air Pressure
>> USB Interface for Transferring Data to Computer
>> Waterproof Version Available
>> Anodised Aluminum Case with Rechargeable Lithium Polymer Battery
>> Optional Expansion Slot for MicroSD Card to Store 1 Billion Measurements Available
>> Includes MSR PC Software to Manage Settings and View, Edit, Export Measured Data
Additional Internal Sensors Available
>> Temperature
>> Humidity
>> Air Pressure (0 to 2000mbar or 0 to 14bar Ranges Available)
>> 3-Axis Acceleration
External Sensors (Temperature, Humidity and Pressure) Available. Call 1-603-746-5524 to Order.
NOTE: All External Sensors are Available as a Special Order.
Large Quantity Discounts Are Available!
All MSR160s are Built to Order: 7-10 Business Day Lead Time.
Data Logger w/ 4 Analog Inputs Specifications
Parameters | Sensors with Analogue Output (Not Supplied) Can Be Connected for Measuring CO, Conductivity, CO2, pH, etc. |
Additional Parameters | >> Temperature (Internal or External Sensor) >> Relative Humidity (Internal or External Sensor) >> Air Pressure (Internal or External Sensor) >> 3-Axis Acceleration (Internal Sensor Only) |
Analogue Inputs | Number: 4 (Each Channel Configured for Separate Ranges) Range: 0 to 3 Volts (Standard)* Resolution: 12 Bit Note: Additional Ranges Available 0 to 20mA, 4 to 20mA, 0.5V to 4.5V, 0 to 5V, 1V to 6V, 0 to 10V, 0 to 12V and 0 to 24V Call 603-746-5524 to Order |
Range | Temperature (Internal Sensor): -20°C to 65°C Temperature (External Sensor): -55°C to 125°C Humidity (w/ Temp Sensor): 0 to 100% RH, -20°C to 65°C Pressure: 0 to 2000 mbar Absolute @ -20°C to 65°C (optional: 0 to 14 bar absolute @ -20°C to 65°C) 3-Axis Acceleration: ±15g @ -20°C to 65°C |
Accuracy | Temperature (Internal Sensor): ±0.5°C (-10°C to 65°C) Temperature (External Sensor): ±0.2°C (-55°C to 125°C) Humidity: ±2% (10 to 85% RH, 0°C to 40°C); ±4% (85 to 95% RH, 0°C to 40°C) Pressure (0 to 2000 mbar): ±2.5mbar (750 to 1100 mbar Absolute, 25°C) Pressure (0 to 14 bar): ±50mbar (1 to 10 bar Absolute, 25°C) 3-Axis Acceleration: ±0.15g @ 25°C |
Sampling Rate | Analog Input: 1000/s to 12 Hours Temperature: 1/s to 12 Hours Humidity: 1/s to 12 Hours Pressure: 1/s to 12 Hours 3-Axis Acceleration: 1/s to 12 Hours |
Data Storage Capacity | Approximately 2,000,000 Total Readings 1 Billion with Optional Standard microSD Card (>4 GB) |
Operating Mode | Push Button Start/Stop |
Operating Conditions | Temperature: -20°C to 65°C |
Storage Conditions | Temperature: 5°C to 45°C Humidity: 10 to 95% RH, non-condensing |
Housing | Standard: Anodised Aluminum Polycarbonate Not Encapsulated Waterproof: Anodised Aluminum Polycarbonate Encapsulated |
Color | Blue, Anthracite |
Power Supply | Rechargeable Lithium Polymer Battery (900 mAh) >> USB Connection to PC Recharges Unit |
Media | Air, Various Liquids |
Standards Compliance | Standard: IP60, RoHS, WEEE Waterproof: IP67, RoHS, WEEE |
Software Compatible | Windows 7, Vista, XP and 2000 |
Dimensions | 39mm x 23mm x 72mm |
Weight | 80 grams |
MSR160 4 Analog Input Data Logger with 0 to 3 Volt Range | |
Part # | 160B7E3333 |
Base Price | |
Enclosure | |
Internal Temperature Sensor? | |
Internal Humidity Sensor? | |
Internal Pressure Sensor? | |
Internal 3-Axis Acceleration Sensor? | |
microSD Slot w/ 4GB Card |
|
Optional Temperature and Humidity NIST Calibration Service | ||
Standard NIST Temperature Calibration Service >> 1 Point Offset Calibration
>> Traceable to NIST >> Certificate Supplied >> Note: 3 to 5 Day Lead Time for All Calibration Orders |
|
|
Standard NIST Temp/Humidity Calibration Service >> 1 Temperature and Humidity Point Offset Calibration
>> Traceable to NIST >> Certificate Supplied >> Note: 3 to 5 Day Lead Time for All Calibration Orders |
|
External Sensors Available
These External Sensors Replace the Internal Sensors
Call DataloggerMalaysia Sales @ 03-78762460 to Order
>> (#FT2/015) - Temperature Sensor (-55°C to 125°C) with Cable Length of 0.15 Meter
>> (#FT2/040) - Temperature Sensor (-55°C to 125°C) with Cable Length of 0.40 Meter
>> (#FT2/100) - Temperature Sensor (-55°C to 125°C) with Cable Length of 1.00 Meter
>> (#FT2/160) - Temperature Sensor (-55°C to 125°C) with Cable Length of 1.60 Meter
>> (#FH/015) - Humidity Sensor with Cable Length of 0.15 Meter
>> (#FH/040) - Humidity Sensor with Cable Length of 0.40 Meter
>> (#FH/100) - Humidity Sensor with Cable Length of 1.00 Meter
>> (#FH/160) - Humidity Sensor with Cable Length of 1.60 Meter
>> (#FP/015) - Air Pressure Sensor (2.0 bar) with Cable Length of 0.15 Meter
>> (#FP2/015) - Air Pressure Sensor (14 bar) with Cable Length of 0.15 Meter
>> (#FP/040) - Air Pressure Sensor (2.0 bar) with Cable Length of 0.40 Meter
>> (#FP2/040) - Air Pressure Sensor (14 bar) with Cable Length of 0.40 Meter
>> (#FP/100) - Air Pressure Sensor (2.0 bar) with Cable Length of 1.00 Meter
>> (#FP2/100) - Air Pressure Sensor (14 bar) with Cable Length of 1.00 Meter
>> (#FP/160) - Air Pressure Sensor (2.0 bar) with Cable Length of 1.60 Meter
>> (#FP2/160) - Air Pressure Sensor (14 bar) with Cable Length of 1.60 Meter
Data Logger w/ 4 Analog Inputs Applications
- Vehicle Manufacture and Development in Automotive Industry
- Measurement and Testing Applications for Railways and Trains
- Measurements in Outdoor Applications like Wind Power and Other Energy Installations
- Food Processing Industry, Laboratory Technology and In Patient Monitoring