SmartReader Plus 7 Data Logger - DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR | DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR

SmartReader Plus 7 Data Logger

 

The SmartReader Plus 7 data logger records process signals easily. With seven input channels it is
ideal for monitoring (through commercially available transducers) a wide variety of measurement parameters. All process signals can be displayed in their own engineering units using the simple equation editor in the TrendReader Software.

Required with SmartReader Plus 7 Data Logger

>> TrendReader 2 software

Required for Ethernet Connectivity

>> TrendReader 2 Software with USB Cable Kit (#TR2-USB)
>> Read the Networking and Remote Communications Guide

SmartReader Plus 7 Logger Features

  • Monitoring wind speed, flow, tank level, pressure, current, voltage
  • SCADA troubleshooting

SmartReader Plus 7 Logger Specifications

General Specifications
Channels Eight: One internal thermistor and 7 analog inputs
Memory Size Available in 32 KB (21,500 readings), 128 K (87,000 readings)  or 1.5 MB (1,048,000 readings) versions
Size 107 x 74 x 22 mm. (4.2” x 2.9” x 0.9”)
Weight 110 grams (3.75 ounces)
Case Material Noryl Plastic
External Connector Removable screw-type terminal strip with Common (-) connection
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing)
Clock Accuracy ±2 seconds per day
Battery 3.6 volt Lithium, 1 Amp-Hour
Battery Life 10 year warranty (under normal use), factory replaceable
Power Consumption 5 to 10 microamps (continuous)
Sampling Methods 1. Continuous (First-in, First-out – not available with sample rates faster than 8 seconds)
2. Stop when full (Fill-then-stop)
Sampling Rates User selectable rates from 25 per second to 1 reading every 8 hrs. (BP-101 Battery Pack or PS-201 Power Supply required for sample rates faster than 8 seconds)
Resolution 12 bit (1 part in 4,096)
Mounting Magnetic backing or locking eyelet
Software Compatiblity Windows 3.1, 95, 98, 2000, ME, NT, XP, Vista (32-bit), Windows 7 (32-bit and 64-bit)
Product Approvals Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets radiated and conducted emission require ments for the Interference Causing Equipment Standard f or Digital Apparatus of Industry Canada (ICES-003). IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE)
Resistance to X-Rays Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport x-ray machine). Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5”

 

Input Impedance for Analog Input Channels
Input Type Input Impedance
0 to 2.5 volts DC Greater than 1M ohm
0 to 5.0 volts DC Greater than 1M ohm
0 to 10.0 volts DC Greater than 1M ohm
0 to 200 millivolts DC Greater than 1M ohm
0 to 25 milliamps DC 20 Ohm


Description Part Number
Standard Models
SmartReader Plus 7 32KB, 8-channels: one temp, seven channels of mixed voltage/current SRP-007
SmartReader Plus 7 128KB, 8-channels: one temp, seven channels of mixed voltage/current SRP-007-128K
SmartReader Plus 7 1.5MB, 8-channels: one temp, seven channels of mixed voltage/current SRP-007-1-5M
0-25mA Versions
SmartReader Plus 7 32KB, 8-channels: one temp, seven channels 0-25mA SRP-007-25MA
SmartReader Plus 7 128KB, 8-channels: one temp, seven channels 0-25mA SRP-007-25MA-128K
SmartReader Plus 7 1.5MB, 8-channels: one temp, seven channels 0-25mA SRP-007-25MA-1-5M
0 to 2.5 Volts Versions
SmartReader Plus 7 32KB, 8-channels: one temp, seven channels 0-2.5vdc SRP-007-0-2-5V
SmartReader Plus 7 128KB, 8-channels: one temp, seven channels 0-2.5vdc SRP-007-0-2-5V-128K
0 to 5 Volts Versions
SmartReader Plus 7 32KB, 8-channels: one temp, seven channels 0-5vdc SRP-007-0-5V
SmartReader Plus 7 32KB, 8-channels: one temp, seven channels 0-5VDC (Limited Quantity - 1 Available) SRP-007-0-5V-32K--U--
SmartReader Plus 7 128KB, 8-channels: one temp, seven channels 0-5vdc SRP-007-0-5V-128K
SmartReader Plus 7 1.5MB, 8-channels: one temp, seven channels 0-5vdc SRP-007-0-5V-1-5M
0 to 10 Volts Versions
SmartReader Plus 7 32KB, 8-channels: one temp, seven channels 0-10vdc SRP-007-0-10V
SmartReader Plus 7 128KB, 8-channels: one temp, seven channels 0-10vdc SRP-007-0-10V-128K
SmartReader Plus 7 1.5MB, 8-channels: one temp, seven channels 0-10vdc SRP-007-0-10V-1-5M
Software Kit - 1 Required
TrendReader 2 Software with RS-232 Cable (IC-101) and Manual for Smart Reader series TR2-RS232
TrendReader 2 Software with USB Interface Cable (IC-102) and Manual for Smart Reader series TR2-USB
TrendReader 2 Software CD Only (interface cable and manual not included), for SmartReader Plus, Smart Reader, IAQ and OWL Loggers TR2-Standard
AC Voltage Transducers
Voltage Transducer for logging single phase, 120 Volt, 60 Hz electrical systems, for loggers with a 0-5 Volt channel VT-1P
Voltage Transducer for logging three phases, 480 Volt, 60 Hz electrical systems, for loggers with a 0-5 Volt channel VT-3P
Standard NIST Calibration Service
Standard NIST Temperature Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders CAL-NIST-TEMP
Standard NIST DC Voltage Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders CAL-NIST-DCVOLT
Standard NIST 4-20mA Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders CAL-NIST-420MA
Optional Accessories
Fast Sampling Battery Pack BP-101
Network/Fast Sampling Power Supply - 120V - North American Version PS-201-NA
Network/Fast Sampling Power Supply - 220V - European Version PS-201-EU
Extra RS-232 Interface Cable for SmartReader, SmartReader Plus and Nautilus loggers IC-101
USB Serial Adapter CABLE-USB232

Fast Sampling with Battery Pack or External 120 Volt Power Supply
For sampling rates faster than once every 8 seconds, the Smart Reader Plus data loggers require the use of an external 120 volt power supply (#PS-201) or fast sampling battery pack (#BP-101).

The fast sampling battery pack has replaceable "AAA" batteries and 8" (20cm) cable attached, with a male stereo jack on the end. The stereo jack is plugged into the communication port on the Smart Reader Plus data logger.

The 120 Volt Power Supply is required when network length is greater than 50' , more than 3 loggers are on the network, or for sampling rates greater than 8 seconds on the SmartReader Plus Loggers.