MSR165 Shock and Vibration Data Logger - DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR | DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR

MSR165 Shock and Vibration Data Logger

 
>> Capable of Making 1600 Acceleration (Shock, Vibrations) Measurements per Second in All 3 Axes
>> 32 Measurement Values are Recorded Even 
Before the Event Takes Place
>> Measurement Range of ±15g in -20°C to 65°C Temperature Range
>> Also Records Temperature, Humidity, Air Pressure, Light and 4 Analog Input Signals
>> MSR PC Software Manages Settings and View, Edit, Export Measured Data
>> Includes CD Software and USB Cable

Additional Measurement Parameters Available
>> Temperature
>> Humidity
>> Pressure (Air) 
>> Light Level
>> Any Analog Input Signal
External Sensors (Temperature, Humidity, Pressure and Light) and 4 Analog Inputs Available. Call 03-78762460 to Order

NOTE: All External Sensors are Available as a Special Order.
Large Quantity Discounts Are Available!

Shock and Vibration Data Logger Specifications

Measured Parameters >> 3-Axis Acceleration (Built-in Internal)
>> Temperature (Internal or External)
>> Relative Humidity (Internal or External)
>> Air Pressure (Internal or External)
>> Light (Internal)
>> Analog Input Signal (External)
Acceleration Range: ±15g
Accuracy: ±0.15G @25°C
Temperature Range: -20°C to 65°C (Internal); -55°C to 125°C (External)
Accuracy: ±0.3°C (Internal);±2.0°C (External)
Humidity Range: 0 to 100% RH, -20°C to 65°C
Accuracy: ±2% (10 to 85% RH, 0°C to 40°C); ±4% (85 to 95% RH, 0°C to 40°C); ±0.5°C (0°C to 65°C)
Pressure Range: 0 to 2000 mbar Absolute or 0 to 14 Bar Absolute
Accuracy: ±2.5mbar (750 to 1100 mbar Absolute, 25C); ±0.5°C (0°C to 65°C)
Light Type: SFH 5712 Osram
Range: 0 to 65,000 lx
Accuracy: 100 to 65,000 lx, Max ±5% Linearity Error, Max Sensitivity at 500 nm
Resolution: 4 lx
Temperature Coefficient: 0°C to 50°C, <0.2%/K
Analog Input Number: 4 (Each Channel Configured for Separate Ranges)
Range: 0 to 3.0 Volts (Standard)**
Resolution: 12 Bits
Note: Additional Ranges Available
0 to 20mA, 4 to 20mA, 0.5V to 4.5V, 0 to 5V, 1V to 6V, 0 to 10V, 0 to 12V and 0 to 24V
Call 03-78762460 to Order
Sampling Rate Acceleration: Up to 1600/s
Temperature: 1/s to 12 Hours
Humidity: 1/s to 12 Hours
Pressure: 1/s to 12 Hours
Light Level: 1/s to 12 Hours
Data Storage Capacity Approximately 2,000,000 Total Readings
Additional Storage Available with Standard SD (>4 GB) Card
Operating Conditions Temperature: -20°C to 65°C
Storage Conditions Temperature: 5°C to 45°C
Humidity: 10 to 95% RH, non-condensing
Color Blue, Anthracite
Operating Mode Push Button Start/Stop
Recording Mode Set Bookmark or Start and Stop Recording
Power Supply Rechargeable Lithium Polymer Battery (900mAh)
>> USB Connection to PC recharges unit
>> At a Measurement Rate of 1600/s up to once every 12 Hours, 3-Axis Acceleration data can be recorded over a period of 6 months
Housing Enclosure Anodised Aluminum Case, PC, Not Encapsulated , Waterproof
Media Air, Various Liquids
Standards Compliance RoHS/WEEE, IP67
Software Compatible Windows 7, Vista, XP and 2000
Dimensions 39mm x 23mm x 72mm
Weight 64 grams


Part # 165B8A
Base Price  
Internal Temperature Sensor?  
Internal Humidity Sensor?  
Internal Pressure Sensor?  
An Internal Light Sensor or 4 Analog Inputs are Available. An MSR165 Can NOT Have Both since there is only 1 Remaining Slot within the Logger.
Internal Light Sensor?  
4 Analog Inputs? (0 to 3.0 Volts) **
Additional Ranges for the Analog Inputs Include:
0 to 20mA, 4 to 20mA, 0.5V to 4.5V, 0 to 5V, 1V to 6V, 0 to 10V, 0 to 12V and 0 to 24V
Call 03-78762460 to Order
Optional Temperature and Humidity NIST Calibration Service
Standard NIST Temperature Calibration Service Standard NIST Temperature Calibration Service
>> 1 Point Offset Calibration
>> Traceable to NIST
>> Certificate Supplied
>> Note: 3 to 5 Day Lead Time for All Calibration Orders


Part #: CAL-NIST-TEMP

Standard NIST Temperature Calibration Service Standard NIST Temp/Humidity Calibration Service
>> 1 Temperature and Humidity Point Offset Calibration
>> Traceable to NIST
>> Certificate Supplied
>> Note: 3 to 5 Day Lead Time for All Calibration Orders


Part #: CAL-NIST-RH

Documentation (pdf)

MSR165 User Manual
MSR165 SD Card Manual

Shock and Vibration Data Logger Applications

  • Measure Vibrations in Servo-Axles
  • Oscillations at a Tool Carousel in Manufacturing Machine
  • Monitoring of Transport Goods

The following external sensors are available for the Shock and Vibration Recorder
These External Sensors Replace the Internal Sensors.

>> (#F11015) - Temperature Sensor (-55°C to 125°C) with Cable Length of 0.15 Meter
>> (#F11040) - Temperature Sensor (-55°C to 125°C) with Cable Length of 0.40 Meter
>> (#F11100) - Temperature Sensor (-55°C to 125°C) with Cable Length of 1.00 Meter
>> (#F11160) - Temperature Sensor (-55°C to 125°C) with Cable Length of 1.60 Meter

>> (#F20015) - Humidity Sensor with Cable Length of 0.15 Meter
>> (#F20040) - Humidity Sensor with Cable Length of 0.40 Meter
>> (#F20100) - Humidity Sensor with Cable Length of 1.00 Meter
>> (#F20160) - Humidity Sensor with Cable Length of 1.60 Meter

>> (#F30015) - Air Pressure Sensor (2.0 bar) with Cable Length of 0.15 Meter
>> (#F31015) - Air Pressure Sensor (14 bar) with Cable Length of 0.15 Meter
>> (#F30040) - Air Pressure Sensor (2.0 bar) with Cable Length of 0.40 Meter
>> (#F31040) - Air Pressure Sensor (14 bar) with Cable Length of 0.40 Meter
>> (#F30100) - Air Pressure Sensor (2.0 bar) with Cable Length of 1.00 Meter
>> (#F31100) - Air Pressure Sensor (14 bar) with Cable Length of 1.00 Meter
>> (#F30160) - Air Pressure Sensor (2.0 bar) with Cable Length of 1.60 Meter
>> (#F31160) - Air Pressure Sensor (14 bar) with Cable Length of 1.60 Meter

>> (#F40015) - Light Sensor with Cable Length of 0.15 Meter
>> (#F40040) - Light Sensor with Cable Length of 0.40 Meter
>> (#F40100) - Light Sensor with Cable Length of 1.00 Meter
>> (#F40160) - Light Sensor with Cable Length of 1.60 Meter

>> (#B21114) - 4 Analogue Inputs (0 to 3.0 Volts, 12 bit, Max. 2 External Sensors Possible, Light Sensor Not Available.)