The SmartReader Plus 2 is a self-contained data logger that can monitor and record temperature and relative humidity - right out of the box. The on-board RH (Relative
Humidity) sensor is temperature compensated, permitting reliable, worry-free RH readings. For remote sensing of temperature and RH, simply attach ACR’s external temperature/RH probe, or for remote temperature sensing, attach up to two of ACR's thermistor probes.
Required with Temperature Data Logger
>> TrendReader 2 software
Required for Ethernet Connectivity
>> TrendReader 2 Software with USB Cable Kit (#TR2-USB)
>> Read the Networking and Remote Communications Guide
NOTE: NIST Calibration is available.
Large Quantity Discounts Are Available!
SmartReader Plus 2 Logger Features
- Very Lightweight
- Can Record over 87,000 Readings
- 4 Channels
SmartReader Plus 2 Logger Specifications
General Specifications | |
---|---|
Channels | Four (one for the internal temperature sensor, one for the internal RH sensor and two for remote measurements of temperature and RH [with ACR's EH-020A probe]) |
Memory | 128 K (87,000 readings) |
Size | 107 x 74 x 22 mm. (4.2” x 2.9” x 0.9”) |
Weight | 110 grams (3.75 ounces) |
Case Material | Noryl Plastic |
External Connector | Removable screw-type terminal strip with Common (-) connection |
Operating Limits | -40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing) |
Clock Accuracy | ±2 seconds per day |
Battery | 3.6 volt Lithium, 1 Amp-Hour |
Battery Life | 10 year warranty (under normal use), factory replaceable |
Power Consumption | 5 to 10 microamps (continuous) |
Sampling Methods | 1. Continuous (First-in, First-out – not available with sample rates faster than 8 seconds) 2. Stop when full (Fill-then-stop) |
Sampling Rates | User selectable rates from 25 per second to 1 reading every 8 hrs. (BP-101 Battery Pack or PS-201 Power Supply required for sample rates faster than 8 seconds) |
Resolution | 12 bit (1 part in 4,096) |
Mounting | Magnetic backing or locking eyelet |
Software Compatiblity | Windows 3.1, 95, 98, 2000, ME, NT, XP, Vista (32-bit), Windows 7 (32-bit and 64-bit) |
Software Requirements | TrendReader 2 Software and Interface Kit |
Product Approvals | Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets radiated and conducted emission require ments for the Interference Causing Equipment Standard f or Digital Apparatus of Industry Canada (ICES-003). IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE) |
Resistance to X-Rays | Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport x-ray machine). Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5” |
Internal Temperature Sensor | |
---|---|
Type | Negative Temperature Coefficient Thermistor. 10,000 ohms @ 25°C (77°F) |
Accuracy | ± 0.2°C, over the range of 0 to 70°C (±0.3°F over the range of 32 to 158°F) |
Range | -40 to 70°C (-40 to 158°F) |
Resolution | 0.03°C (0.05°F) at 25°C (77°F). Better than 0.07°C (0.12°F) between -25°C (-13°F) and 70°C (158°F). Better than 0.13°C (0.23°F) between -40°C (-40°F) and -25°C (-13°F) |
Internal Humidity Sensor | |
---|---|
Type | Capacitive thin polymer film |
Range | 0 to 95% RH (non-condensing) |
Acccuracy | ± 3% RH from 10 to 90% RH (-20 to 40°C [-4 to 104°F]) |
Resolution | Better than 0.04% RH between 25 and 60% RH @ 25°C (77°F) |
Environmental Conditions | Like all relative humidity sensors, when exposed to contaminants and/or extreme environmental conditions, accuracy degradation could result. For maximum long term stability, sensor should not be exposed or subjected to organic solvents, corrosive agents (strong acids, SO2, H2SO4, Cl2, HCl, H2S, etc.), and strong bases (compounds with PH greater than 7). Dust settling on the sensor surface will not affect sensor performance except possibly to decrease the speed of response. |
Description | Part Number | |||
SmartReader Plus 2 128 KB, 4-channels: temperature, RH and optional external temp and RH probes | SRP-002-128K | |||
Software Starter Kit - 1 Required | ||||
TrendReader 2 Software with RS-232 Cable (IC-101) and Manual for Smart Reader series | TR2-RS232 | |||
TrendReader 2 Software with USB Interface Cable (IC-102) and Manual for Smart Reader series | TR2-USB | |||
TrendReader 2 Software CD Only (interface cable and manual not included), for SmartReader Plus, Smart Reader, IAQ and OWL Loggers | TR2-Standard | |||
External RH/Temp Probe | ||||
Remote relative humidity/temperature probe, range 10 to 90% RH, -20° to 40°C (-4° to 104°F) | EH-020A | |||
External Temperature Thermistor Probes | ||||
Low Temperature Penetration Probe, stainless steel, 3 1/2" probe w/handle. Thermistor type. Range: -60° to 55°C (-75° to 130°F). Length: 10' (3 meters) | ET-004 | |||
Low Temperature Probe, stainless steel, 1 X 3/16" probe. Thermistor type. Range: -60° to 55° (-75° to 130°F). Length: 20' (6 meters) | ET-004-GP | |||
General Purpose Temperature Probe, stainless Steel, 1 X 3/16" probe. Thermistor type. Range: -35° to 95°C (-30° to 200°F). Length: 20' (6 meters) | ET-016 | |||
Waterproof Temperature Probe, Stainless Steel, 1 X 3/16" probe. Thermistor type. Range: -40? to 105?C (-40? to 221?F). Length: 20' (6 meters) | 35-0035 | |||
Stainless Steel, 1 X 3/16" probe. Thermistor type. Range: 10° to 170°C (50° to 335°F). Length: 20' (6 meters) | ET-081 | |||
Oven Temperature Probe, stainless steel, 1 X 3/16" probe. Thermistor type. Range: 70° to 255°C (155° to 490°F). Length: 20' (6 meters) | ET-086 | |||
Pipe Surface Temperature Probe, stainless steel, 1 X 3/16" probe. Thermistor type. Range: -35° to 95°C (-30° to 200°F). Length: 20' (6 meters) | ET-016-SMP | |||
Standard NIST Calibration Service | ||||
Standard NIST Temperature Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders | CAL-NIST-TEMP | |||
Standard NIST Temp/RH Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders | CAL-NIST-RH | |||
Optional Accessories | ||||
Fast Sampling Battery Pack | BP-101 | |||
Network/Fast Sampling Power Supply - 120V - North American Version | PS-201-NA | |||
Network/Fast Sampling Power Supply - 220V - European Version | PS-201-EU | |||
Extra RS-232 Interface Cable for SmartReader, SmartReader Plus and Nautilus loggers | IC-101 | |||
USB Serial Adapter | CABLE-USB232 |
Fast Sampling with Battery Pack or External 120 Volt Power Supply
For sampling rates faster than once every 8 seconds, the Smart Reader Plus data loggers require the use of an external 120 volt power supply (#PS-201) or fast sampling battery pack (#BP-101).
The fast sampling battery pack has replaceable "AAA" batteries and 8" (20cm) cable attached, with a male stereo jack on the end. The stereo jack is plugged into the communication port on the Smart Reader Plus data logger.
The 120 Volt Power Supply is required when network length is greater than 50' , more than 3 loggers are on the network, or for sampling rates greater than 8 seconds on the SmartReader Plus Loggers.