The HOBO RH & Temp Logger measures and records temperature and humidity readings. The logger can log up to 7,943 8-bit samples without downloading to a PC. The datalogger features user selectable samling rate of 0.5 seconds to 9 hours, programmable start time/date and 1 year battery life.
Included with Data Logger
>> Mounting Kit (Hook/Loop, Magnet, and Tape)
Required with the Data Logger
>> BoxCar Software Kit
NOTE: NIST Calibration is available.
Large Quantity Discounts Are Available!
Due to New CE Requirements, this product is No Longer Available for EU Countries, Check out the U12-011 Temp RH Data Logger As An Alternative.
Temperature, RH Data Logger Features
- 2 Channel Data Logger with Internal Temperature and Humidity Sensors
- Internal Temperature Sensor on 4" Wire can Extend from Case
- Readout and Relaunch Logger with Optional HOBO Shuttle
- Programmable Start Time/Date
- Nonvolatile EEPROM Memory Retains Data Even If Battery Fails
- Blinking LED Light Confirms Operation
- Battery Level Indication at Launch
- Requires BoxCar Software Kit for Operation and Data Manipulation
Temperature, RH Data Logger Specifications
Data Storage Capacity | 7,943 8-bit Samples/Readings |
Sampling Rate | 0.5 Second to 9 Hours (User Selectable) |
Operating Range | Temperature: -20°C to 70°C (-4°F to 158°F) Humidity: 0 to 95% RH non-condensing, non-fogging |
Operating Modes | Stop When Full Wrap-Around When Full |
Temperature Sensor | Range: -4°F to 158°F (-20°C to 70°C) Range Outside Case: -40°F to 248°F (-40°C to 120°C) Accuracy: ±1.27°F (±0.7°C) at +70°F Resolution: 0.7°F (0.4°C) at +70°F Response Time (Sensor Inside Case): 15 min. Response Time (Sensor Outside Case): 1 min. |
Humidity Sensor | Range: 25% to 95% RH at 80°F for Intervals < 10 Sec, Non-Condensing and Non-Fogging Accuracy: ±5% Response Time (In Air): 10 min. Sensor Operating Environment: 5°C to 50°C (41°F to 122°F) , Non-Condensing and Non-Fogging |
Drop Proof | Up to 5 ft. |
Time Accuracy | ±1 Minute per Week at 20°C (68°F) |
Storage Range | Temperature: -40°C to 75°C (-40°F to 167°F) |
Battery Life | Typically 1 Year |
Battery | 3-Volt CR-2032 Lithium Battery (User Replaceable) |
Standards Compliance | CE |
Weight | 29 grams (1 oz) |
Dimensions | 61mm x 48mm x 20mm (2.4" x 1.9" x 0.8") |
Description | Part Number | Qty 10+ | ||
HOBO RH/Temp, 2 channel Data Logger | H08-003-02 | call | ||
Software Kits - 1 Required | ||||
BoxCar Pro 4.3 Software and Serial Cable Kit | BCP4.3-ON | call | ||
BoxCar 3.7 Software and Serial Cable Kit | BC3.7 | call | ||
Standard NIST Calibration Service | ||||
Standard NIST Temperature Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders | CAL-NIST-TEMP | call | ||
Standard NIST Temp/RH Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders | CAL-NIST-RH | call | ||
Optional Accessories | ||||
USB Serial Adapter | CABLE-USB232 | call | ||
Extra/Replacement Batteries (pack of 5) - CR2032 Lithium Batteries | HRB-TEMP-5 | call | ||
Extra Serial Interface Cable | Cable-PC-3.5 | call | ||
Glacier Clear Xtreme Protective Case (3.93" x 2.4" x 0.94") | T1000.1 | call | ||
Blue Xtreme Protective Case (3.93" x 2.4" x 0.94") | T1000.4 | call | ||
Replacement RH Sensor for H8 Indoor Loggers | HUM-UPS-500 | call |