Squirrel 2010 Data Logger - DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR | DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR

Squirrel 2010 Data Logger

 
 
>> Measures Current, Voltage, Resistance and Temperature
>> 4 Differential or 8 Single Ended Channels with 8 Digital Channels to Trigger or Stop Logging
>> Programmed Using LCD Display and 4 Integral Buttons or Software
>> 2 Alarm Outputs and 2 Pulse Counter Inputs (64kHz and 100Hz) 
>> 0.1% Accuracy (Range + 0.1% of Reading) 
>> Stores up to 1.8 Million Readings 
>> RS232 Port for Modem and Wireless Connection via Interface Units (Sold Separately)
>> External Input Sensors Sold Separately
>> Includes Case, Starter Guide, USB Cable, Certificate of Conformance, Connection Plugs with Cable Ties, Resistors, Battery and SquirrelView Software for Setup and Data Download

SQ2010 Kit Includes
>> Hard Case with Lined Fitted Foam
>> SquirrelView Plus Software
>> Getting Started Guide with Certificate of Conformity
>> Universal Adapter and USB Cable
>> Set of Connection Plugs Complete with Cable Ties
>> (4) Precision Resistors for 4-20mA Connection
>> (2) C Type Alkaline Batteries
>> Small Electrical Screw Driver

The Grant Squirrel SQ2010 is available for purchase via Bank Wire Transfer Only. Contact Sales @ 03-78762460 for further details.

Squirrel 2010 Data Logger Squirrel 2010 Data Logger Kit
>> 4 Differential or 8 Single-Ended Analog Inputs
>> LCD Display, Alarms and RS232 Port
>> Includes Case, Batteries, Unversal Adaptor and USB Cable, Connection Plugs, Resistors, Getting Started Guide w/ Certificate of Conformance, SquirrelView Plus Software, User Manual and Small Electrical Screw Driver
Part #: SQ2010KIT
Call To Purchase
03-78762460
Squirrel 2010 Data Logger Squirrel 2010 Data Logger
>> Open Box: 1 Available
>> 4 Differential or 8 Single-Ended Analog Inputs
>> LCD Display, Alarms and RS232 Port
>> Includes Case, Batteries, USB Cable, Certificate of Conformance, Software and User Manual
Part #: SQ2010--U--
Call To Purchase
03-78762460
Squirrel 2010 Data Logger Squirrel 2010 Data Logger
>> 4 Differential or 8 Single-Ended Analog Inputs
>> LCD Display, Alarms and RS232 Port
>> Includes Case, Batteries, USB Cable, Certificate of Conformance, Software and User Manual

Part #: SQ2010
Call To Purchase 03-78762460

Accessories

Grant Serial Ethernet Converter Grant Serial Ethernet Converter
>> Netport RS-232 Ethernet Converter
>> Converts RS232 Output to Ethernet
>> Allows the Logger to Connect to Ethernet Network
>> Requires Ethernet Network Connection

Part #: SQ20A801
Call To Purchase
03-78762460
Grant Modem Adapter Grant Modem Adapter
>> Remote Connection to Logger Using GSM Cellular Network
>> Operates on Dual Band Versions (900 MHz and 1800 MHz)

Part #: SQ20A802
Call To Purchase
03-78762460

Squirrel 2010 Specifications

Data Channels 8 Single-Ended Analog Channels
or
4 Differential Analog Channels
Channel Expansion No
Universal Input Yes
Voltage Ranges -6 to 25, -0.6 to 2.4, ±0.3 Volts, -0.15 to 0.15, -0.075 to 0.075, -6 to 12, -6 to 6, -3 to 3, -0.6 to 1.2, -0.6 to 0.6
(Differential and Single Ended)
Common Mode 25 Volts
Current Range Differential: 4 to 20mA, ±30mA
(Requires External 10R Shunt)
Thermocouple Range J-Type: -200°C to 1200°C
K-Type: -200°C to 1372°C
N-Type: -200°C to 1300°C
R-Type: -50°C to 1768°C
S-Type: -50°C to 1768°C
T-Type: -200°C to 400°C
(Differential and Single Ended)
Resistance Range
(All 2 Wire)
0 to 1,250 R, 0 to 5,000 R
(0 to 300,000R , 0 to 20,000 R
Thermistor Range U & UU-Type: -50°C to 150°C
Y-Type: -50°C to 150°C
S-Type: -30°C to 150°C
Pt100/1000 Range
(2-Wire)
-200°C to 850°C
Internal Reference Temperature -50°C to 150°C
Pulse Count Range 0 to 100Hz (1 Input)
0 to 64kHz (1 Input)
0 to 16,000,000 Count
Digital State/Event Ranges 8 State Inputs or 1 x 8 Bit Binary
Digital/Alarm Outputs 2 Open Drain FETs, 18 Volts, 0.1 Amp
A/D Resolution 24 Bit
Accuracy 0.1% of Range + 0.1% of Reading
Clock Resolution 1s/10ppm Normal Mode - Each Input Sampled at a maximum rate of 1 reading per second. Double-speed (mains reject off) - one input can be sampled at 10 readings per second and all others are sampled at a maximum rate of 1 reading per second.
Number of Intervals 4
Data Scaling Yes
Data Statistics Yes from within SquirelView Plus PC Software
Calculated Channels Yes up to 16
Data Storage Capacity 1.8 Million Measurements/Readings
Display/Keypad 128*64 Dot Graphical Display, 4 Button Keypad
Power Source User-Replaceable (2) C Alkaline Battery
Battery Life 5 Days (Continuous Usage Sampling All Channels 1/Second)
External Power 8 to 28 Volts DC & USB When Plugged In
Sensor Power Output 5 Volts at 50mA, External 8 to 28 Volts at 100 mA
(When Sensor is Connected)
Networking via RS-232 to Ethernet Adaptor (Part #SQ20A801)
Modem Support Via RS232 Modem (GSM Modem Part # SQ20A802)
Actions & Triggers AS SQ2020/40 Although 2 Alarm Outputs
PC Setup Yes, SquirrelView Compatible
Front Panel Setup Via 4 Integral Keys. All Essential Functionality Available via Key Pad (Channel Configuration, Start/Stop Logging , etc.) Other Advanced Functions (Calculated Channels and Channel Descriptions) are Available Via Connection to a PC Running SquirrelView
Stored Setups 6
Third Party Programming Dependant on 20XX Driver Suite
Operating Range Temperature: -20°C to 65°C
Standards Compliance CE
Weight 0.7 kilograms
Dimensions 17.5 cm x 13.5 cm x 0.55 cm (175mm x 135mm x 55mm)

Application Notes (pdf)

Understanding the Differences Between State, Event and Pulse Datalogging. (.pdf 300K)

Documentation (pdf)

Squirrel 2010 Getting Started Guide (.pdf 1.3 MB)
Squirrel 2010 Logging Speed Guide (.pdf 100 KB)
Squirrel Software Compatibility Guide (.pdf 28 KB)