AEMC Thermocouple Simple Logger II

  • Monitor and Record Temperatures Using 2 External 
    Thermocouple Probes
  • Compatible with Type J, K, T, N, E, R and S Thermocouples
  • Store up to 240,000 Samples/Readings
  • 3 User Selectable Storage Modes
  • 5 LED Indicators Quickly and Clearly Display Logger Status
  • Includes DataView Software for Real-Time Waveform Display, Analysis and Report Generation
  • Requires a Thermocouple Probe
Monday, 18 June 2012 04:48

Exhaust System Temperature Monitoring

  • Monitor and Record Temperatures from Exhaust Manifold Systems for Compliance with State and Federal Rules
  • Recorded Readings are Stored to PC and Software Displays Graphs of Temperature Readings
Monday, 18 June 2012 03:25

Bed Bug Eradication & Extermination

  • Data Loggers Monitor Temperature Levels in Room(s) while Bed Bugs are Heated and Exterminated
  • Monitor the Disinfection Process and Areas to Guarantee Extinction
Sunday, 17 June 2012 21:25

Data Logger Batteries

Extech Data Logger Batteries

 

Part Number

Product

AAA-ALK-BAT

4 pack AAA Batteries

 

Graphtec America Data Logger Batteries

Part Number

Product

B-517

Graphtec Battery Pack

 

Onset Data Logger Batteries

Part Number

Product

HRB-TEMP-5

Extra/Replacement Batteries (pack of 5) - CR2032 Lithium Batteries

HP-B

Extra/Replacement 3.6V 1/2 AA Lithium Battery

AAA-ALK-BAT

4 pack AAA Batteries

 

HOBO Weather Station Batteries

Part Number

Product

HWSB-LI

AA Batteries (Lithium) 4 Pack

 

Lascar Data Logger Batteries

Part Number

Product

HP-B

Extra/Replacement 3.6V 1/2 AA Lithium Battery

 

Star-Oddi Data Logger Batteries

Part Number

Product

BAT-KIT

Star-Oddi Battery replacement service kit for Starmon/Seamon

BAT-3.6V

Star-Oddi Spare lithium battery, 3.6V

 

Supco Data Logger Batteries

Part Number

Product

U9VL-FP

9 Volt Lithium Battery, 1200 mAH

 

TandD Data Logger Batteries

Part Number

Product

AAA-ALK-BAT

4 pack AAA Batteries

 

Sunday, 17 June 2012 20:49

NIST Calibration Services

NIST Calibration Services

DataloggerMalaysia offers a variety of calibration services for Temperature, Humidity, Voltage and Pressure devices. Each device is calibrated to the manufacturer's specifications using test equipment traceable to National Institute of Standards and Technology (NIST). Calibration stickers are affixed to each device and returned with a "Calibration certificate" listing "as found" and "as left" readings. The calibration certificate provides the documentation required to meet many USDA, EPA, FDA and GLP (Good Laboratory Practice) and GMP (Good Manufacturing Practice) quality standards.

We offer single point or multiple point calibration for all products and it usually takes 3-5 business days for calibrations to get through the lab.

Temperature Calibration Services

Temperature calibration is performed with a Kaye Model M2801/IRTD-400, IPTS-68 This service is priced at $49.00 for a single point and $19.00 for each additional point. Discounts are available for multiple unit calibrations, please contact or call sales @ +607- 4352540 for a price quote. Temperature calibration is available in the following range: -50°C to 150°C (41°F to 122°F). A sample temperature calibration certificate is available here

Temperature & Humidity Calibration Services

Temperature & Humidity (RH) calibration is performed with an Edgetech Model DS2 Dew Point Hygrometer.This service is priced at $96.00 for a single point and $29.00 for each additional point. Discounts are available for multiple unit calibrations, please contact or call sales @ +607- 4352540 for a price quote. Temp. & RH calibration is available at 25°C or 40°C with select common RH values. The options are:

25°C and 30% RH

25°C and 50% RH

25°C and 70% RH

Or

40°C and 40% RH

40°C and 60% RH

40°C and 80% RH

A sample temperature / humidity calibration certificate is available here.

Gauge Pressure Calibration Services

Pressure calibration is performed with an Ametek Pneumatic Pressure Tester, Model HK-500. This service is priced at $59.00 for a single point and $20.00 for each additional point. Discounts are available for multiple unit calibrations, please contact or call sales @ +607- 4352540 for a price quote. Gauge pressure (Pipe Pressure) calibration is available in the following range: 10 to 400 PSI. A sample pressure calibration certificate is linked here.

DC Voltage Calibration Service 

Voltage calibration is performed with a Fluke Voltage/Current Calibrator, Model 5500A. This service is priced at $10.00 per point. Discounts are available for multiple unit calibrations, please contact or call sales @ +607- 4352540 for a price quote. DC voltage calibration is available in the following range: 0 to 1000 Volts DC A sample DC Voltage calibration certificate is available here.

4/20mA Current Calibration Services 

Calibration of 4/20mA current devices is performed with a Fluke Voltage/Current Calibrator, Model 5500A. This service is priced at $10.00 per point. Discounts are available for multiple unit calibrations, please contact or call sales @ +607- 4352540 for a price quote. A sample 4/20mA calibration certificate is available here.

Definitions

NIST: U.S. National Institute of Standards & Technology.

Calibration is simply the process of comparing the unknown with a reference standard and reporting the results. For Example: Applied= 1.3V, Indicated=1.26V (or Error =-0.04V) Calibration may include adjustment to correct any deviation from the value of the standard.

Verification, as it related to calibration, is the comparison of the results against a specification, usually the manufacturer's published performance figures for the product. (e.g. Error=-0.04V, Spec=±0.03V, "FAIL"). Some calibration labs include a specification status statement on their Certificate of Calibration. (ie the did/did not comply with a particular spec).

Conformance, especially regarding the meaning of a Certificate of Conformance. Typically available when an instrument is purchased, it is generally recognized that such a document has little value as an assurance of product performance. Of course, the manufacturer expects that the product conforms to its specifications but, in this sense, the document simply affirms that the customer's purchase order/contract requirement has been duly fulfilled.

 

Saturday, 16 June 2012 11:58

Images of ACR Data Loggers

 

JR-1000

JR-1001

Nautilus

TRH-1000

 

OWL-100

OWL-200

OWL-300

OWL-400

 

OWL-500

PowerWatch

Smart Button

Smart Reader 1

 

Smart Reader 2

Smart Reader 3

Smart Reader 4

Smart Reader 5

 

 

Smart Reader 6

Smart Reader 7

Smart Reader 8

Smart Reader 9

 

 

Smart Reader Plus 1

Smart Reader Plus 2

Smart Reader Plus 3

Smart Reader Plus 4

 

Smart Reader Plus 4

Smart Reader Plus 5

Smart Reader Plus 6

Smart Reader Plus 7

 

 

Smart Reader Plus 8

Smart Reader Plus 9

Smart Reader Plus 10

 

 

  • Paperless chart recorder eliminates the need for replacement charts and pens
  • Stores 49,000 temperature and humidity readings for later transfer to PC
  • Simultaneous numerical and graphical display of humidity with temperature or dew point, date/time, min/max, alarm
  • Measure and Record Temperature, Humidity and Dewpoint Using External Sensor Probe
  • Measurement Range of -40°C to 55°C (Temp); 0 to 100% (Humidity); 0 to 55°C (Dewpoint)
  • LCD Display, Alarms and Polycarbonate Case
  • Available in 115 VAC and 220 VAC Power Adapters
  • Includes Temp/RH Sensor and 60 Paper Charts
Saturday, 16 June 2012 08:31

Temperature Chart Recorder

  • 3 Temperature Ranges and 4 Chart Speeds
  • LED Display and Single or Continuous Chart Rotation
  • 4" Submersible SS External Temperature Probe with 15ft Cable
  • AC Powered with Battery Backup Option
  • Available in Celsius or Fahrenheit Versions
  • Includes 60 Assorted Charts, 2 Pens and External Temperature Probe
Saturday, 16 June 2012 08:25

Supco Universal Chart Recorder

  • Requires a Sensor Probe, sold separately
  • Automatic Probe Detection
  • Field Replaceable Sensor Probes
  • Field Calibration of Sensor Probes
  • Independent Channel Alarms
  • Battery Backup
  • Backlit 2 Line LCD display