Track-It USB Voltage Data Loggers - DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR | DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR

Track-It USB Voltage Data Loggers

 

>> Measures and Records Temperature (-20°C to 85°C) and DC Voltage (0 to 500 milliVolts)
>> Stores a Total of 64,000 Samples/Readings (32,000 Temperature and 32,000 Voltage)
>> User-Configurable Alarms and LED Indicators
>> 2 Second to 24 Hour Logging Rate (User-Configured)
>> Direct USB Interface for Set-up and Data Download
>> 1 Year User-Replaceable Battery with 4-Digit LCD Display and Alarms
>> One-Click Export Function Automatically Exports Stored Data into Excel Spreadsheet
>> User-Configurable Start Date and Time via Software
>> Additional 1 Volt, 5 Volt, 10 Volt and 4-20mA Modules Available
>> Includes PC Software and Lithium Coin Cell Battery

USB Voltage Logger Specifications

Data Storage Capacity 64,000 Total Samples/Readings
(NOTE: If Attaching an Analog Input Module, Only 32,000 Temperature Readings Available)
Sampling Rate 2 Seconds to 24 Hours (User-Selectable via Software)
Voltage Range: 0 to 500 mV DC
Accuracy: ±0.5% of Full Scale 
Resolution: ±0.1 mV
Temperature Range: -20°C to 85°C (-4°F to 185°F)
Accuracy (0°C to 50°C): ±1.0°C
Accuracy (20°C to 85°C): ±2.0°C
Resolution: 0.4°C (1.0°F)
Repeatability: ±0.1°C (±0.2°F)
Time Accuracy ±1 Minute per Year
Triggers Number: 2 Independant Triggers
Modes: Instanteous, Button Control, On Alarm, Time and Date, Day of Week
Battery 3-Volt CR-2032 Lithium Battery (User Replaceable)
Battery Life Typically 1 Year @ 1 Minute Sampling Rate
Operating Modes >> Continuous
>> Start and Stop Using Buttons on Front of Logger
>> Start and Stop at Predetermined Date/Time
>> Start When Alarm Condition is Sensed
Display Type: 4 Digit LCD
Functions: Temperature, Engineering Units, Alarms, Record Mode, Battery Condition, Time/Data Stamp and Memory
LED User Programmable: Alarm Indicator, Recordings and Triggers
Button User Programmable: View Display, Record On/Off, Reset Alarms, Reset Timer
Alarms (2) User Programmable Visual Alarms. High or Low
Communications Interface Direct USB Connection
Software Track-It Software Required (Included)
OS Compatibility Windows XP, Vista and Windows 7 (32 and 64-Bit)
Standards Compliance CE
Dimensions 103.2mm x 16.7mm x 25.4mm (4.06" x 0.66" x 1.00")

 

Track-It Voltage Logger with 0 to 500mV Range Track-It Voltage Logger with 0 to 500mV Range
>> Range: 0 to 500 mVolts DC
>> 2 Input Channels for Measuring DC Voltage
>> Stores 32,000 DC Voltage and 32,000 Temp Readings
>> Includes Track-It Software and Battery
Part #: 5396-0511
Standard NIST DC Voltage Calibration Service Standard NIST DC Voltage Calibration Service
>> 1 Point (per Channel) Offset Calibration
>> Traceable to NIST
>> Certificate Supplied
>> Note: 3 to 5 Day Lead Time for All Calibration Orders


Part #: CAL-NIST-DCVOLT

Optional Accessories

USB Docking Ball Extension USB Docking Ball Extension
>> 5ft USB 2.0 Cable with Upright Stand
>> Handy Extension Cable For All USB Devices
Part #: USB-DB
CR2032 Batteries CR2032 Batteries
>> Pack of 5
Quantity Price Each
1 - 9  
10+  
Part #: HRB-TEMP-5
Replacement Rubber Sleeve for Track-It Loggers Replacement Rubber Sleeve for Track-It Loggers
>> Splash-Proof Protective Rubber Cover
>> Included with Temperature and Humidity Track-It Loggers
Part #: 5396-9903
Track-It Software on CD Track-It Software on CD
 
Part #: 5396-9902
Locking Protective Wall Cover Locking Protective Wall Cover
>> Clear Plastic
>> Dimension: 3 7/8" x 3 1/2" x 2 1/2"
>> Vertical or Horizontal Mounting
>> Includes Locking Key and Mounting Hardware
Part #: BTG-EK

Optional Analog Input Modules

These additional input modules can be swaped or interchanged to measure different voltage and current ranges.

500 mV Analog Input Module 500 mV Analog Input Module
>> Range: 0 to 500 mVolts DC
>> 2 Input Channels for Measuring DC Voltage
>> Stores 32,000 DC Voltage Readings
>> Requires DC Voltage Sensor
Part #: 5396-0501
1 Volt Analog Input Module 1 Volt Analog Input Module
>> Range: 0 to 1 Volt DC
>> 2 Input Channels for Measuring DC Voltage
>> Stores 32,000 DC Voltage Readings
>> Requires DC Voltage Sensor
Part #: 5396-0502
1 Volt Analog Input Module 5 Volt Analog Input Module
>> Range: 0 to 5 Volts DC
>> 2 Input Channels for Measuring DC Voltage
>> Stores 32,000 DC Voltage Readings
>> Requires DC Voltage Sensor
Part #: 5396-0503
1 Volt Analog Input Module 10V Analog Input Module
>> Range: 0 to 10 Volts DC
>> 2 Input Channels for Measuring DC Voltage
>> Stores 32,000 DC Voltage Readings
>> Requires DC Voltage Sensor
Part #: 5396-0504
1 Volt Analog Input Module 20 mA Analog Input Module
>> Range: 0 to 20mA Current
>> 2 Input Channels for Measuring Current
>> Stores 32,000 Current Readings
Part #: 5396-0505

Documentation (pdf)

Track-It Logger Quick Start GuideTrack-It Logger Operating Instructions

Documentation for DC Voltage and Current Logger

Track-It Logger Quick Start Guide