The TandD RTR-52 data logger with external temperature sensor can measure and record temperatures from -60 to +155°C. The logger features wireless data transmission to a collector (Sold Separately) within 100 meters, battery life of 6 months with 1 lithium battery, alarm notifications, 15 sampling intervals and 16K of data storage.Large Battery Option Available.
Required with Wireless Temp Logger
>> Wireless Data Collector (#RTR-5W, #RTR-57U or #RTR-50)
Each Wireless Temp Logger Includes
>> O-Ring, Screws and Silica Gel
>> User Manual
>> Battery
NOTE: NIST Calibration is available.
Large Quantity Discounts available!
Wireless Temp Logger Features
- Single Channel Wireless Temperature Data Recorder with External Sensor
- 15 Different Sampling Interval (1 second to 60 minutes)
- Monitor Temperature Conditons and Transmit Captured Data Wirelesssly
- Audible Alarm when Low/High Thresholds are Met
- Large Capacity Battery Pack Available
- Requires Wireless Data Collector (#RTR-57U ) , Wireless Communications Port (#RTR-50) or Wireless Network Station (# RTR-5W)
- Includes Software, Battery and User Manual
Wireless Temp Logger Specifications
Measurement Channel | 1 External Temperature Sensor |
External Sensor | TR-5106 Temperature Sensor w/ 0.6m Cable Length |
Temperature Sensor Range | -60°C to +155°C |
Resolution | 0.1°C |
Accuracy | Avg. ±0.3°C (-20 to +80°C) ±0.5°C (-40°C to -20°C / +80°C to+110°C) ±1.0°C (-60°C to -40°C / +110°C to +155°C) |
Data Storage Capacity | 16,000 Samples |
Recording Interval | 1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes ( Total of 15 choices ) |
Water Resistance | IP64 (Continuous Spray) |
Recording Mode | Endless: Overwrite Oldest Data when Capacity is Full One-time: Stop Recording when Capacity is Full |
LCD Display Items | Current Readings / Recording Settings / Battery Life Warning / Over Measurement Range Warning / Amount of Recorded Data |
Power | Lithium Battery (LS14250(SAFT)) or AC Adaptor (sold separately) |
Battery Life | RTR-52: Approx. 6 months RTR-52L: 2.5 Years (Battery life depends on measurement environment, recording interval and battery performance) |
Dimension | 62 mm x 47 mm x 19 mm (excluding protrusions / antenna length 20mm) |
Wireless Method | FCC Part 15 Section 249 / IC RSS-210 |
Communication Speed | When downloading data (Wireless) about 2,000 readings per minute [Collection of a full unit of data= about 420 seconds (optical communication= about 160 seconds)] |
Transmission Distance | Up to 100 Meters (Line of Sight and No Obstructions) |
Unit Temp. Resistance | -40°C to 80°C |
Description | Part Number | |||
TandD Wireless Temperature Logger with External Sensor | RTR-52 | |||
TandD Wireless Temperature Logger w/ External Sensor - Large Battery Pack Version w/o Batteries | RTR-52L | |||
TandD Wireless Temperature Logger w/ External Sensor - Large Battery Pack Version includes Battery | RTR-52L-B | |||
Wireless Collector - 1 Required | ||||
TandD Wireless Data Collector w/ Software and USB Cable | RTR-57U | |||
Wireless Data Collector and Repeater | RTR-50 | |||
TandD Wireless Data Collector with full Network Connectivity | RTR-5W | |||
Standard NIST Calibration Service | ||||
Standard NIST Temperature Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders | CAL-NIST-TEMP | |||
Optional External Sensors | ||||
TandD Flexible 1.8" Temperature Sensor | TR-5101 | |||
TandD Flexible 24" Temperature Sensor | TR-5106 | |||
TandD Stainless Steel Temperature Probe | TR-5220 | |||
TandD Stainless Steel Temperature Probe w/ Tapered End | TR-5320 | |||
TandD Stainless Steel Temperature Probe w/ Pointed End | TR-5420 | |||
TandD Water Immersible Temperature Sensor | TR-5530 | |||
Optional Accessories | ||||
TandD 110 Volt AC Adapter | AD-0638 | |||
Wall Mount for RTR-5 and RTR-500 Series Loggers | TR-05K3 | |||
CFR 21 Part 11 Secure Software (Limited Quantity - 1 Available) | VLD-5-US--U-- | |||
CFR 21 Part 11 Secure Software | VLD-5-US | |||
TandD Temperature Sensor Extension Cable | TR-2C30 | |||
Extra/Replacement 3.6V 1/2 AA Lithium Battery | HP-B | |||
TandD Large Capacity Battery Pack (w/o Battery) | RTR-05B1 | |||
TandD External Power Pack w/ 110V AC Adapter | RTR-05A1 | |||
Tadiran Lithium Battery, 3.6 Volts, C Cell | TL2200/S | |||
Wall Mount for RTR-5 and RTR-500 Series Loggers w/ Large Battery Pack | TR-05K3L |
Large Battery Pack Option: The Large Battery Pack provides continuous use for up to 2.5 years. The battery will allow you to measure and record over long periods of time whether the unit is in transit or in a distant place.
Note: Battery life will depend on the recording environment, recording interval, communication frequensy, and ambient temperature. The above battery life test was carried out using brand new batteries and in no way do we guarantee a battery's life. Removing the battery and not replacing it will result in a loss of all recorded data.
Documentation:
TandD RTR-5 series of loggers User Manual (pdf)
RTR-57 Data Collector Manual (pdf)