ACR 4 Channel Data Logger: Pressure, Temperature and 2 for optional RH/Temp Probes

The SmartReader Plus 4 data logger provides easy monitoring and troubleshooting of pneumatic control systems. The datalogger is completely self-contained with a 1/4” quick-release pressure fitting to allow a fast and trouble-free connection. As an added bonus, this data logger can also monitor temperature internally, or temperature and RH externally. (RH sensors/probes and thermistor temperature probes sold separately).

Several Pressure Ranges and Data Storage Capacities Available

Required with Temperature Data Logger
>> TrendReader 2 Software

Required for Ethernet Connectivity

>> TrendReader 2 Software with USB Cable Kit (#TR2-USB)
>> Read the Networking and Remote Communications Guide

NOTE: NIST Calibration is available.

Large Quantity Discounts Are Available!

SmartReader Plus 4 Pressure Logger Specifications

Channels Four (4). Internal Ambient Temperature, Pressure and two (2) optional temperature and Humidity
Accuracy ±0.5% of full scale @25°C (77°F)
Pressure Sensor Multiple Ranges Available:
1. 0 to 10" WC (2.5 kPa) Gauge @ 0.006" Resolution
2. 0 to 5 psi (30 kPa) Gauge @ 0.003 psi (0.02 kPa) Resolution
3. 0 to 30 psi (200 kPa) Absolute @ 0.015 psi (0.1 kPa) Resolution
4. 0 to 30 psi (200 kPa) Gauge @ 0.015 psi (0.1 kPa) Resolution
5. 0 to 100 psi (700 kPa) Absolute @ 0.05 psi (0.34 kPa) Resolution
6. 0 to 100 psi (700 kPa) Gauge @ 0.05 psi (0.34 kPa) Resolution
7. 0 to 150 psi (1000 kPa) Gauge @ 0.05 psi (0.34 kPa) Resolution
Temperature Sensor Negative Temperature Coefficient Thermistor. 10,000 ohms @ 25°C (77°F)
Temperature Accuracy ± 0.2°C, over the range of 0 to 70°C (±0.3°F over the range of 32 to 158°F)
Temperature Range -40 to 70°C (-40 to 158°F)
Temperature Resolution 0.03°C (0.05°F) at 25°C (77°F). Better than 0.07°C (0.12°F) between -25°C (-13°F) and 70°C (158°F). Better than 0.13°C (0.23°F) between -40°C (-40°F) and -25°C (-13°F)
Memory Available in 32KB (21,500 Readings) or 128KB (87,000 Readings)
External Connector Removable Screw-Type Terminal Strip with Common (-) Connection
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
Clock Accuracy +/- 2 Seconds per Day
Power Consumption 5 to 10 microamps (continuous)
Sampling Methods Continuous: First-In, First Out (not available with Sample Rates faster than 8 seconds)
Stop when Full: (Fill-then-Stop)
Sampling Rates User Selectable Rates from 25 per second to 1 Reading Every 8 Hours. (#BP-101 Battery Pack or #PS-201 Power Supply required for sample Rates Faster than 8 seconds)
Resolution 12 Bit (1 part in 4,096)
Product Approvals Meets Part 15 for Digital Devices of the Code of Federal Regualtions of the FCC
Meets Radiated and Conducted Emission Requirements for the Interfernce Causing Equipment Standard for Digital Apparatus of Industry Canada (ICES-003). IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE)
Resistance to X-Rays Tested for protection against a 160kV dose @ 5mA for 30 Seconds (150 mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport x-ray machine).
Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts)
IR 192-28 curies @ 320 second exposure source to object distance 5"
Battery 3.6 Volt Lithium, 1 Amp-Hour
Battery Life 10 Year Warranty (under normal use), Factory Replaceable
Case Material Noryl Plastic
Mounting Magnetic Backing or Locking Eyelet
Size 107mm x 74mm x 22mm (4.2" x 2.9" x 0.9")
Weight 110 grams (3.75 Ounces)
Software Compatiblity Windows 3.1, 95, 98, 2000, ME, NT, XP, Vista (32-bit), Windows 7 (32-bit and 64-bit)
Price  
Data Storage Capacity  
Pressure Range  
Description Part Number
Software Kit - 1 Required
TrendReader 2 Software with RS-232 Cable (IC-101) and Manual for Smart Reader series TR2-RS232
TrendReader 2 Software with USB Interface Cable (IC-102) and Manual for Smart Reader series TR2-USB
TrendReader 2 Software CD Only (interface cable and manual not included), for SmartReader Plus, Smart Reader, IAQ and OWL Loggers TR2-Standard
External RH/Temp Probe
Remote relative humidity/temperature probe, range 10 to 90% RH, -20° to 40°C (-4° to 104°F) EH-020A
External Temperature Thermistor Probes
Low Temperature Penetration Probe, stainless steel, 3 1/2" probe w/handle. Thermistor type. Range: -60° to 55°C (-75° to 130°F). Length: 10' (3 meters) ET-004
Low Temperature Probe, stainless steel, 1 X 3/16" probe. Thermistor type. Range: -60° to 55° (-75° to 130°F). Length: 20' (6 meters) ET-004-GP
General Purpose Temperature Probe, stainless Steel, 1 X 3/16" probe. Thermistor type. Range: -35° to 95°C (-30° to 200°F). Length: 20' (6 meters) ET-016
Waterproof Temperature Probe, Stainless Steel, 1 X 3/16" probe. Thermistor type. Range: -40? to 105?C (-40? to 221?F). Length: 20' (6 meters) 35-0035
Stainless Steel, 1 X 3/16" probe. Thermistor type. Range: 10° to 170°C (50° to 335°F). Length: 20' (6 meters) ET-081
Oven Temperature Probe, stainless steel, 1 X 3/16" probe. Thermistor type. Range: 70° to 255°C (155° to 490°F). Length: 20' (6 meters) ET-086
Pipe Surface Temperature Probe, stainless steel, 1 X 3/16" probe. Thermistor type. Range: -35° to 95°C (-30° to 200°F). Length: 20' (6 meters) ET-016-SMP
Standard NIST Calibration Service
Standard NIST Temperature Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders CAL-NIST-TEMP
Standard NIST Temp/RH Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders CAL-NIST-RH
Optional Accessories
Fast Sampling Battery Pack BP-101
Network/Fast Sampling Power Supply - 120V - North American Version PS-201-NA
Network/Fast Sampling Power Supply - 220V - European Version PS-201-EU
Extra RS-232 Interface Cable for SmartReader, SmartReader Plus and Nautilus loggers
USB Serial Adapter CABLE-USB232

Fast Sampling with Battery Pack or External 120 Volt Power Supply
For sampling rates faster than once every 8 seconds, the Smart Reader Plus data loggers require the use of an external 120 volt power supply (#PS-201) or fast sampling battery pack (#BP-101).

The fast sampling battery pack has replaceable "AAA" batteries and 8" (20cm) cable attached, with a male stereo jack on the end. The stereo jack is plugged into the communication port on the Smart Reader Plus data logger.

The 120 Volt Power Supply is required when network length is greater than 50' , more than 3 loggers are on the network, or for sampling rates greater than 8 seconds on the SmartReader Plus Loggers.