PowerPad 8335 Power Quality Analyzer
>> Measurement of TRMS Voltage, TRMS Current, Frequency, Neutral Current, Harmonic Angles and Rates
>> Record and Display Trend Data for 25 Different Variables
>> Calculates Crest Factors (voltage and Current), K Factor for Transformers, Short-Term Flicker, 3-Phase Voltage Unbalance, Power Factor, Displacement Power Factor and Tangent Factor
>> Real-Time Display of Phasor Diagrams Including Values and Phase Angles
>> Software Configuration of all Functions and Parameters
>> 2GB Internal Memory
>> Display and Analyze Real-Time Data on Your PC
>> Download, Display and Analyze all recorded Data
>> Display Waveforms, Trend Graphs, Harmonic Spectrums, Text Summaries, Transients, Event Logs and Stored Alarms
The Powerpad Includes
>> (5) 10ft Black Voltage Leads
>> (5) Black Allilgator Clips
>> (12) Color-Coded Rings
>> RS-232 DB9F Optically Coupled Serial Cable
>> NiMH Battery
>> 110/240 Volt Power Adapter with US Power Cord
>> DataView Software and User Manual
>> Large Classic Tool Bag
>> Soft Carrying Pouch
Specifications
Sampling Frequency | 256 Samples/Cycle |
Data Storage | 2GB SD Card |
Voltage (TRMS) | Phase-to-Phase: 1000 Volts Phase-to-Neutral: 1000 Volts |
Current (TRMS) | MN Clamp: 0 to 6A/120A ot 0 to 240A SR Clamp: 0 to 1200 Amps MR Clamp: 0 to 1000Aac, 0 to 1400Adc MiniFlex: 0.1A to 1000A AmpFlex: 0 to 6500 Amps |
Frequency (Hz) | 40 to 69 Hz |
Other Measurements | kW, kVAR, kVA, PF, DPF, kWh, kVARh, kVAh, K-Factor, Flicker |
Harmonics | 1st to 50th, Direction, Sequence |
Power Source | 9.6 NiMH Rechargeable Battery Pack External AC Supply: 110/230 VAC ±10% (50/60 Hz) |
Battery Life | Display On: Approximately 8 Hours Display Off: Approximately 35 Hours (Record Mode) |
Communication Port | Optically Coupled RS-232 |
Display | 1/4 VGA (320 x 240) Color LCD |
Dimensions | 9.8" x 7.8" x 2.6" (250mm x 200mm x 67mm) |
Weight | 4.3 lbs (1.95Kg) |
Safety Rating | EN 61010-1, 600V Cat. IV**, Pollution Degree 2 |
Applications
- Power Distribution Circuits
- In-Plant Troubleshooting
- Monitor Pad Mount Transformers
- Determine Harmonic Problems
- Monitor Phase Unbalances
- Determine Transformer K-Factor
- Check Motor Inrush