Shark 200S 3-Phase Submeter and Data Logger - DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR | DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR

Shark 200S 3-Phase Submeter and Data Logger

 
>> 0.2% Accuracy Class Revenue Certifiable Energy with KYZ Output and Demand Submeter
>> Utility Demand Profiles wtih User-Configured Block Window or Rolling Window Demand
>> Utility Grade Test Pulse for Revenue Metering and Accuracy Verification/Certification
>> Multifunction Measurements, 3 Line 0.56" LED Display and % of Lead Bar for Analog Perception
>> Standard RS485 (Modbus and DNP 3.0) and IrDA Port (PDA or Pocket PC)
>> 2 MB of Storage for Data Logging Historical Trends, Limit Alarms and Sequence of Events
>> Optional WiFi/RJ45 Ethernet Communications Connection and IP Address Assignment 
>> Energy Usage Data Collection and Analysis Using Optional E-Billing EXT™ Software
>> Includes CommunicatorEXT 3.0 for Windows Single-User License Software

The Shark Products is Built to Order and Can Have a Lengthy Lead Time to Delivery.

This product Line is NOT RETURNABLE FOR CREDIT Unless There Are Defects Due to Manufacturer Error.

NOTE: Large Quantity Discounts Available!

Specifications

Voltage Inputs Universal Voltage Input
Line to Neutral: 20 to 576 Volts
Line to Line: 0 to 721 Volts
Input Withstand Capability: Meets IEEE C37.90.1 (Surge Withstand Capability)
Programmable Voltage Range: Any PT Ratio
Supports: 3 Element Wye, 2.5 Element Wye, 2 Element Delta, 4 Wire Delta Systems
Burden: 0.14VA at 120 Volts; 0.36VA Per Phase Max at 600 Volts
Input Impedance: 1M Ohm/Phase
Pickup Voltage: 20 Volts AC
Connection: 7 pin 0.400" Screw Terminal Block
Fault Withstand: Meets IEEE C37.90.1 (Surge Withstand Capability)
Current Inputs Class 10: 5 Amp Nominal, 10 Amp Maximum
Class 2: 1 Amp Nominal, 2 Amp Secondary 
Programmable Current: Any CT Ratio
Burden: 0.005VA per Phase Max at 11 Amps
Pickup Current: 5mA (Class 10); 1mA (Class 2)
Connections: Screw Terminal - #6-32 Screws 
Fault Withstand: Meets IEEE C37.90.1 (Surge Withstand Capability)
Accuracy
(Class 10)
Voltage - Line to Neutral: 0.1% of Reading 
Voltage - Line to Line: 0.1% of Reading 
Current: 0.1% of Reading 
+/- Watts: 0.2% of Reading 
+/- Wh: 0.2% of Reading 
+/- VARs: 0.2% of Reading 
+/- VARh: 0.2% of Reading 
VA: 0.2% of Reading 
VAh: 0.2% of Reading 
PF: 0.2% of Reading 
Frequency: ±0.03 Hz 
%THD: ±5.0% 
%Load Bar: ±1 Segment
Isolation Inputs/Outputs are Galvanically Isolated to 2500 Volts AC
KYZ Pulse Type: Form C Contact
Resistance: 35 Ohms Max
Peak Voltage: 350 Volts DC
Continuous Load Current: 120 mA
Peak Load Current: 350 mA (10ms) 
Off State Leakage Current: 1uA (@350 VDC)
Sensing Method >> RMS
>> Sample Over 400 Readings/Cycle on All Channels Simultaneously
Logging >> Historical Trends 
>> System Events
>> Limit/Alarms
Update Rate Watts, VAR and VA: 100msec @ 60 Hz - Every 6 Cycles
All Other Parameters: 1 Second @ 60 Hz - Every 60 Cycles
Communication Ports Number of Ports: 2
Type: RS485 (Modbus ASCII, Modbs RTU and DNP 3.0 Protocols); Optical IrDA 
Baud Rate: 9,600 to 57,600
Port Address: 1 to 247
Bit, Parity: 8 Bit, No Parity
Wireless Ethernet >> 802.11b Wireless, WiFi or 10BaseT Ethernet (RJ45)
>> 128 bit WEP Encryption: 128 bit Wireless Security
>> Modbus TCP Protocol
Standards Compliance CE
IEC 687 (0.2% Accuracy)
ANSI C12.20 (0.2% Accuracy)
ANSI (IEEE) C37.90.1 Surge Withstand
ANSI C62.41 (Burst)
IEC1000-4-2 - ESD
IEC1000-4-3 - Radiated Immunity
IEC1000-4-4 - Fast Transient
IEC1000-4-5 - Surge Immunity
Faceplate Rating: NEMA 12 (Water Resistant)
Power Supply Burden: 16 VA Max.
Type: 90 to 400 Volts AC and 100 to 370 Volts DC - Universal AC/DC Supply
Operating Conditions Temperature: -20°C to 70°C 
Humidity: 0 to 95% RH Non-Condensing
Storage Conditions Temperature: -20°C to 70°C
Humidity: 0 to 95% RH Non-Condensing
Dimensions 7.9" x 7.5" x 3.1" (200.1mm x 191.3mm x 79mm)
Antenna Length: 4.4" (111.8mm)
Weight 64 oz. (4.0 lbs)

 

Part # EIG-SHARK200-S-50-2-485
Base Price $795.00
Frequency  
Current Input  
Communications  

Standard NIST DC Voltage Calibration Service Standard NIST DC Voltage Calibration Service
>> 1 Point (per Channel) Offset Calibration
>> Traceable to NIST
>> Certificate Supplied
>> Note: 3 to 5 Day Lead Time for All Calibration Orders


Part #: CAL-NIST-DCVOLT


Optional CTs

A Shorting Block (# EL-SB-6TC) is Required with CTs.

EIG 4000/5A Split Core CT EIG 100/5A Split Core CT
>> Measurement Range: 0 to 100 Amps
>> Output: 5 Amp
>> Inside Window Diameter: 0.84" x 2.0"
Part #: EIG-1SP-100-00
EIG 4000/5A Split Core CT EIG 200/5A Split Core CT
>> Measurement Range: 0 to 200 Amps
>> Output: 5 Amp
>> Inside Window Diameter: 0.84" x 2.0"
Part #: EIG-1SP-200-00
EIG 4000/5A Split Core CT EIG 400/5A Split Core CT
>> Measurement Range: 0 to 400 Amps
>> Output: 5 Amp
>> Inside Window Diameter: 2.19" x 3.25"
Part #: EIG-1SP-400-00
EIG 4000/5A Split Core CT EIG 600/5A Split Core CT
>> Measurement Range: 0 to 600 Amps
>> Output: 5 Amp
>> Inside Window Diameter: 2.19" x 3.25"
Part #: EIG-3SP-600-00
EIG 4000/5A Split Core CT EIG 800/5A Split Core CT
>> Measurement Range: 0 to 800 Amps
>> Output: 5 Amp
>> Inside Window Diameter: 2.19" x 3.25"
Part #: EIG-3SP-800-00
EIG 4000/5A Split Core CT EIG 1200/5A Split Core CT
>> Measurement Range: 0 to 1200 Amps
>> Output: 5 Amp
>> Inside Window Diameter: 2.88" x 4.25"
Part #: EIG-5SP-1200-00
EIG 4000/5A Split Core CT EIG 1600/5A Split Core CT
>> Measurement Range: 0 to 1600 Amps
>> Output: 5 Amp
>> Inside Window Diameter: 2.88" x 6.25"
Part #: EIG-7SP-1600-00
EIG 4000/5A Split Core CT EIG 2000/5A Split Core CT
>> Measurement Range: 0 to 2000 Amps
>> Output: 5 Amp
>> Inside Window Diameter: 4.00" x 7.50"
Part #: EIG-91SP-2000-00
EIG 4000/5A Split Core CT EIG 3000/5A Split Core CT
>> Measurement Range: 0 to 3000 Amps
>> Output: 5 Amp
>> Inside Window Diameter: 4.00" x 7.50"
Part #: EIG-91SP-3000-00
EIG 4000/5A Split Core CT EIG 4000/5A Split Core CT
>> Measurement Range: 0 to 4000 Amps
>> Output: 5 Amp
>> Inside Window Diameter: 4.00" x 7.50"
Part #: EIG-91SP-4000-00
Shorting Block - Required
6 Pole CT Shorting Block with Protective Cover 6 Pole CT Shorting Block with Protective Cover
>> 600 Volt Rating
>> 50 Amp Current Rating
>> 4 Pole Configuration
>> 10 AWG Max Wire Range
>> Hinged Clear Plastic Cover w/ Marking Plate
>> Brass Terminals Allow Up to 1/2" Wide Connectors
>> UL Recognized
Part #: EIG-SB-6TC

Documentation

Shark 200S Quick Start Guide (130 KB .pdf)
Shark 200S User Manual (2 MB .pdf)

Applications

  • Utility Power Generation Submetering
  • Substation Telemetry, Voltage Recording, Usage and Analyze Feeder Capacity and Utilization
  • Load Profiling and Planning Estimations with Data Trend PF Distribution and Imbalances
  • Power Quality Studies and System Efficiency Analysis
  • Commerical, Industrial and Campus Metering
  • Analog Meter Replacememt
  • Voltage, Disturbance Recording and Collection with Utility Power Distribution Grid