Fourtec DaqPRO - DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR | DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR

Fourtec DaqPRO

 

>> Portable, Battery and DC Powered Data Acquisition and Logging System with 8 Input Channels
>> Graphical LCD Display with Analysis Functions Shows Temperature, Voltage and Current Readings 
>> Sampling Rate of 4,000 per Second on 1 Channel
>> Stores up to 512,000 Total Samples/Readings (Temperature, Voltage, Current, Pulse or Frequency) 
>> Internal 7.2 Volt Nickel Cadium Rechargeable Battery with 40 Hour Life Between Charges 
>> Scale Readings, On Screen Text Editing of Collected Data and Keypad Setup
>> Includes DaqPRO Lab Software, Carrying Case, AC/DC Adpater, USB Cable, User Manual on CD and NIST Calibration Certificate

DaqPRO 8-Channel Data Logger DaqPRO 8-Channel Data Logger
  • 8 channel data logger with graphical display
  • 16 bit resolution
  • Selectable type for each input: 0-24mA, 0-50mV, 0-10V, NTC, PT-100, Thermocouple, Pulse and frequency
  • Includes Carrying Case, User Manual on CD, Software, USB cable and Certificate of Calibration
Part #: DaqPRO-5300

Standard NIST DC Voltage Calibration Service Standard NIST DC Voltage Calibration Service
>> 1 Point (per Channel) Offset Calibration
>> Traceable to NIST
>> Certificate Supplied
>> Note: 3 to 5 Day Lead Time for All Calibration Orders


Part #: CAL-NIST-DCVOLT

Standard NIST DC Voltage Calibration Service Standard NIST 4-20mA Calibration Service
>> 1 Point Offset Calibration
>> Traceable to NIST
>> Certificate Supplied
>> Note: 3 to 5 Day Lead Time for All Calibration Orders
Part #: CAL-NIST-420MA

Compatible Sensors & Probes

220/12V AC/DC Adapter 220/12V AC/DC Adapter
>> Designed for Europe
>> Limited Quantity: 8 Available

Part #: DT245--U--

Accessories

DatPass Administrative Software Package ( 21 CFR Part 11) with Dongle DatPass Administrative Software Package ( 21 CFR Part 11) with Dongle
>> Used with Other Fourier Software Programs
>> Provides Compliance to FDA 21 CFR Part 11 Regulations

Part #: SFTMCL025A


Solar Cell & Battery for DaqPRO Solar Cell & Battery for DaqPRO
>>
>>
>>

Part #: AC029


DaqPRO Weather Box DaqPRO Weather Box
>>
>>
>>

Part #: 11460A


USB Communications Cable USB Communications Cable
USB communication cable for MicroLog Cradle or DaqPRO

Part #: DT180


110/12V AC/DC Adapter 110/12V AC/DC Adapter
>> Designed for US

Part #: DT246


220/12V AC/DC Adapter 220/12V AC/DC Adapter
>> Designed for UK

Part #: DT282


220/12V AC/DC Adapter 220/12V AC/DC Adapter
>> Designed for Europe
>> Limited Quantity: 8 Available

Part #: DT245--U--


220/12V AC/DC Adapter 220/12V AC/DC Adapter
>> Designed for Europe

Part #: DT245


2-Position Screw Terminal for DaqPro 2-Position Screw Terminal for DaqPro
>>
>>
>>
>>

Part #: ED-1960-ND


DigiKey Terminal Block Plug DigiKey Terminal Block Plug
>> 4 Position
>> 3.81 mm

Part #: ED1962--U--


Specifications

Channels 8 Differential Inputs
Temperature (Internal) Type: Internal Sensor
Range: -25°C to 70°C
Resolution: 0.1°C (1 µV)
Accuracy: ±0.5% FS
Temperature
(NTC Probe)
NTC Type: 10/100KΩ Resistor
Range: -25°C to 150°C
Resolution: 0.05°C
Accuracy: ±0.5% FS
Temperature
(PT-100 Probe)
Channels: (8) PT-100 2-Wire or (4) PT-100 3-Wire 
Range: -200°C to 400°C
Resolution: 0.1°C (7 mΩ)
Accuracy: ±0.5% FS
Thermocouple
(Type J)
Range: -200°C to 1200°C
Resolution: 0.1°C (1 µV)
Accuracy: ±0.5% FS
Cold Junction Compensation Error: ±0.5°C
Thermocouple
(Type K)
Range: -250°C to 1200°C
Resolution: 0.1°C (1 µV)
Accuracy: ±0.5% FS
Cold Junction Compensation Error: ±0.5°C
Thermocouple
(Type T)
Range: -200°C to 400°C
Resolution: 0.1°C (1 µV)
Accuracy: ±0.5% FS
Cold Junction Compensation Error: ±0.5°C
Current Range: 0 to 24 mA
Resolution: 0.47 µA
Accuracy: ±0.5% FS 
Loop Impedance: 195 Ω
Voltage
(0 to 50 mVolts)
Range: 0 to 50 mVolts
Resolution: 3 µV
Accuracy: ±0.5% FS
Voltage
(0 to 10 Volts)
Range: 0 to 10 Volts
Resolution: 200 µV
Accuracy: ±0.5% FS
Input Impedance: 125 kΩ
Pulse Counter
(Input 1 Only)
Input Type: Optocoupler Input
Range: 0to 65,000
Input Signal: 0 to 5 Volts
Input Impedance: 470 Ω
Bandwidth: 0 to 50 Hz
Frequency Meter
(Input 1 Only)
Input Type: Optocoupler Input
Range: 20 to 4,000 Hz
Input Signal: 0 to 5 Volts
Input Impedance: 470 Ω
Analog to Digital Noise: 30 µV rms
Internal Linearity Error: ±0.08% of FSR
Offset Error: 0.1%
Open Collector Output
(Output B)
Maximum Current Sink: 50 mA (Fuse Protected)
Input Impedance: 50 Ω
Offset Error: 0.1%
Data Storage Capacity 512,000 Readings/Samples
Sampling Rate Variable, 1 sample/hour to 4,000 samples/sec, 1 channel
Note: Number of Sensors in Use Limits Max. Sampling Rate. See User Manual (Section 1.2.10) for Details
Sampling Resolution 16 bits
Power Supply Internal Rechargeable 7.2V NiCa Battery
Built in Battery Charger
External 9V to 12V DC input
Battery Life 40 hours Between Charges
Communication USB 1.1 Compliant
Housing Plastic ABS Box
Operating Range Temperature: 0°C to 50°C
Man Machine Interface Full Keyboard Operation - enables manual programming of the logger
Graphic LCD 64x128 pixels
Software DaqLab PC Suite for Windows (Included)
OS Compatibility Windows 95, 98, 2000, ME, XP and Vista
Standards Compliance CE, FCC
Weight 450g (15.87 oz.)
Dimensions 182 mm x 100 mm x 28 mm (7.16" x 3.93" x 1.10")

Documentation: (pdf)

DaqPro and DaqLab User Manual
DaqPro Detailed Specifications
DaqPro Calibration Procedure & Guide
Working with 4-20mA Transducers
DatPass User Guide