True RMS Power Analyzer Datalogger - DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR | DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR

True RMS Power Analyzer Datalogger

The True RMS Power Analyzer and Datalogger is a compact electronic device for analyzing AC
power loads. 4 LCD Displays, fast sampling rate, windows software and data export are just some of the features that makes this the ideal power measurement and analysis tool.

Included with each Power Analyzer Datalogger:
>> Built-in Carrying Case
>> 117 VAC Adapter
>> Power Cord
>> 8 AA Batteries
>> Windows Software and RS-232 Serial Cable

Power Analyzer Features

  • 4 LCD Displays (Watts, Power Factor/VA, Voltage/Hz, Amps)
  • True RMS Voltage and Current Measurements of Sine, Square, Triangular and Distorted Wave Forms with a Crest Factor <5
  • Datalogger stores 1,012 readings with single record storage or continuous datalogging capability
  • Battery or AC Adapter Power Supply Options
  • Sampling Rate: 2.5 Samples per Second
  • Export Data thorugh Software

Power Analyzer Specifications

Watt (Auto Range, AC+DC, Crest Factor <5)
Range Resolution Accuracy Input
200W 0.1W ±(0.9% Reading + 5 Digits) (50/60Hz)
±(5% Reading + 9 Digits) (40 to 400 Hz)
0-300V, 0-20A, PF=0.5 to 1
2000W 1W
NOTE: PF = Watt / (V*A)
Voltage (True RMS, Auto Range, AC+DC, Crest Factor <5)
Range Resolution Accuracy Overload Protection
200W 0.1V ±(0.5% Reading + 5 Digits) (40 to 400Hz) 1000VDC/750VAC
750V 1V
Current (True RMS, Auto Range, AC+DC, Crest Factor <5)
Range Resolution Accuracy (40 to 400 Hz) Overload Protection
2 0.001A ±(0.5% Reading + 5 Digits) 20A, fused
20 0.01A
Frequency (Sensitivity 5V)
Range Resolution Accuracy (40 to 400 Hz)
40Hz to 20kHz 1Hz - 10 Hz ±(0.5% Reading ± 2 Digits)
Display 2000 count LCD Displays
Memory Size 1012 x4 readings (Non-Volatile)
Memory Life 100,000 Memory Writes
Over Range Indication 'OL' displayed on LCD
Sampling Rate 2.5 Samples per Second
Power Source Eight (8) 1.5 Volt 'AA' Batteries or AC Adaptor
Power Consumption Approximately 22 mA
Operating Conditions Temperature: 32°F to 122°F (0°C to 40°C)
Humidity: Less than 80%
Dimensions 13.9" x 11.8" x 3.9" (35.2cm x 30 cm x 10cm)
Weight 3.6 lbs (1.637Kg)


Description Part Number Qty 10+
Extech True RMS Power Analyzer Datalogger 380803 call
Optional NIST Calibration
Standard NIST DC Voltage Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders CAL-NIST-DCVOLT Call
Standard NIST 4-20mA Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders CAL-NIST-420MA call
Accessories
USB Serial Adapter CABLE-USB232 call

Documentation:

Power Analyzer Datasheet
Power Analyzer User Manual

Power Analyser Applications

  • Measure and Audit Power Consumption of Single Phase Devices
  • Evaluate Load Performance Under varying line Conditions
  • Demonistrate Effectiveness of Power Conservation Efforts
  • Characterize Device AC Power Requirements