Thermocouple Meter and Data Logger - DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR | DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR

Thermocouple Meter and Data Logger

 

>> Calculates and Displays Temperature Differentials
>> Requires Types K, J , R, S, E or T Thermocouples or Pt 100Ω RTD Probes (Sold Separately)
>> No Software Required, Data Logs to SD Card (4 GB SD Card Included)

The SD-947 4-channel thermocouple/RTD meter with optional data logging is used when very high or very low temperatures need to be monitored in several areas at once, and the LCD gives immediate access to the current conditions without the need to connect to a pc. Depending on the sensor used, the extremely wide temperature range that can be measured is -100°C to +1700°C (-148°F to +3092°F).

Thermocouple sensors and RTD’s are used in an extremely wide variety of applications such as concrete curing, forensics, and food processing, and are available in many styles.

Readings from the SD-947 can be recorded directly to an SD card (4GB SD Card Included), allowing data to be exported to MS Excel for analysis.

NOTE: Large Quantity Discounts Are Available!

Thermocouple Meter and Data Logger Thermocouple Meter and Data Logger
>> Measures Temperature with External Thermocouples or Pt100 RTDs (Sold Separately)
>> Data Recorded onto SD Card for Analysis
>> No Software Required for Set-up and Data Download
> Includes 4GB SD Card
>> Requires Type K, J, R, S, T or E Type Thermocouple or Pt100 RTD Sensor
Part #: SD-947

Optional Accessories
Reed 9 Volts AC/DC Power Adapter Soft Carry Case with Shoulder Strap
>> Dimensions: 22.8cm x 10.16cm x 5.08cm (9.0" x 4.0" x 2.0")
Part #: CA-05A
Reed 9 Volts AC/DC Power Adapter Reed 9 Volts AC/DC Power Adapter
>> Input Voltage: 100 to 240 Volts AC; 50 Hz
>> Output Voltage: 9 Volts DC/ 1 Amp Output
>> Round Plug with 2.5 mm Diameter
Part #: AP-9VA-110V

Specifications:

Type K Thermocouple Range: -100°C to 1300°C (-148°F to 2372°F)
Accuracy: ±0.4% + 0.5°C (±0.4% + 1.0°F) 
Resolution: 0.1°C (0.1°F)
Type J Thermocouple Range: -100°C to 1200°C (-148°F to 2192°F)
Accuracy: ±0.4% + 0.5°C (±0.4% + 1.0°F) 
Resolution: 0.1°C (0.1°F)
Type T Thermocouple Range: -100°C to 400°C (-148°F to 752°F)
Accuracy: ±0.4% + 0.5°C (±0.4% + 1.0°F) 
Resolution: 0.1°C (0.1°F)
Type E Thermocouple Range: -100°C to 900°C (-148°F to 999.9°F)
Accuracy: ±0.4% + 0.5°C (±0.4% + 1.0°F)
Resolution: 0.1°C (0.1°F)
Type R Thermocouple Range: 0°C to 1700°C (32°F to 3092°F)
Accuracy: ±0.5% + 1.0°C (±0.5% + 2.0°F)
Resolution: 1.0°C (1.0°F)
Type S Thermocouple Range: 0°C to 1500°C (32°F to 2732°F)
Accuracy: ±0.5% + 1.0°C (±0.5% + 2.0°F) 
Resolution: 1.0°C (1.0°F)
Pt 100Ω RTD Range: -199.99°C to 850°C (-327.9°F to 1562°F)
Accuracy: ±0.4% + 1.0°C (±0.5% + 1.8 °F)
External Inputs (4) Thermocouple Channels or (2) RTD Channels
Data Storage Capacity 1GB to 16GB onto External SD Card (4GB SD Card Included)
Sampling Rate 1 Second to 1 Hour
LCD Display Type: Backlight
Size: 52mm x 38mm (2.04" x 1.49")
Download Time Dependent Upon Size of SD Card
Power Source Battery: (6) AA 1.5 Volt Heavy Duty Alkaline
AC/DC Power: 9 Volt Adapter (Optional)
Battery Life Without LCD and SD Card: 120 Hours on Average 
With LCD and SD Card: 35 Hours
Battery Classification Dry Battery, Non-Hazardous
Case Material ABS Plastic
Operating Range Temperature: 0°C to 50°C (32°F to 122°F) 
Humidity: < 85% RH
Standards Compliance IP63
Weight 515 grams (1.13 lbs)
Dimensions 177mm x 68mm x 45mm (6.9" x 2.6" x 1.7")

Documentation: (pdf)

Reed SD-947 Thermocouple Meter and Data Logger Datasheet