Lascar Thermocouple Data Logger w/ LCD Display - DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR | DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR

Lascar Thermocouple Data Logger w/ LCD Display

>> Measure and Record Using J, K, or T Type Thermocouple 
>> Stores 32,000 Temperature Readings 
>> High Contrast LCD Display
>> 2 User-Programmable Alarm Thresholds
>> Red and Green LED Indicator Lights 
>> Immediate, Delayed and Push-to-Start Logging
>> USB Interface for Set-up and Data Download
>> Accepts Type J, K and T Thermocouple Probes
>> Includes PC Software, 1/2 AA Battery and K-Type Thermocouple

NOTE: Large Quantity Discounts Are Available!

USB Thermocouple Logger w/ Display Specifications

Measurement Range K-Type TC: -200°C to 1300°C (-325°F to 2372°F)
J-Type TC: -130°C to 900°C (-202°F to 1652°F)
T-Type TC: -200°C to 350°C (-328°F to 662°F)
Thermocouple Probe
(Included)
Type: 4" Stainless Steel K-Type
Range: 0°C to 400°C (32°F to 752°F)
Yellow Type K Connector
Part #: EL-TC-K4-15
Resolution 0.5°C (1.0°F)
Accuracy ±1.0°C (±2.0°F)
Data Storage Capacity 32,000 Samples
Sampling Rate 1 Second to 12 Hours
Operating Range Temperature: -10°C to 40°C (14°F to 104°F)
(Note: Logger Should Not be Subjected to Temperatures Outside Operating Range)
Operating Modes Immediate
Delayed
Push-to-Start
Battery User Replaceable 1/2AA 3.6V Lithium
Battery Life Typically 1 Year (Dependant on Sampling Rate and Environment)
OS Compatibility Windows XP, Vista, 7 (32-bit and 64-Bit Versions)
LED Green: Recording and Logging
Red: Alarm Thresholds Met
Display Functions Recent Logged Temperature Reading
Maximum Logged Temperature
Minimum Logged Temperature
Alarm Visual - Blinking Red LED (2 User Programmable)
LCD Display Recording and Logging
Minimum, Maximum and Last Stored Temperature Reading
Standards Compliance IP61, RoHS


Lascar USB Thermocouple Logger with LCD Display
>> Records Readings from a J, K, or T Type Thermocouple
>> Stores 32,000 Temperature Readings
>> High Contrast 4 Digit LCD Display
>> Includes 1/2AA Battery, Software and Type K Thermocouple
Quantity Price Each
1 - 4  
5 - 9  
10+  
Part #: EL-USB-TC-LCD
Standard NIST Temperature Calibration Service Standard NIST Temperature Calibration Service
>> 1 Point Offset Calibration
>> Traceable to NIST
>> Certificate Supplied
>> Note: 3 to 5 Day Lead Time for All Calibration Orders

Part #: CAL-NIST-TEMP
Temp:

Accessories for USB Thermocouple Data Logger

Handheld Data Collector and Viewer
>> Stores 8.5 Million Readings from Lascar USB Loggers
>> 2.8" TFT Display with Touch Screen
>> Rechargeable Battery with 8 Hour Life
>> Includes USB Cable, Start Guide and Lithium Battery
Quantity Price Each
1 - 9  
10+  
Part #: EL-DATAPAD
Protective Rubber Casing for Lascar DataPad
>> Rubber Casing
>> Fits Snuggly Around DataPad
>> Protects From Scratches and Light Knocks
Part #: EL-DATAPAD-BOOT
3.6V 1/2 AA Lithium Battery
>> 3.6 Volt (1/2 AA) Lithium Battery
Quantity Price Each
1 - 9  
10+  
Part #: HP-B
USB Docking Ball Extension USB Docking Ball Extension
>> 5ft USB 2.0 Cable with Upright Stand
>> Handy Extension Cable For All USB Devices
Part #: USB-DB
Locking Protective Wall Cover
>> Clear Plastic
>> Dimension: 6 3/8" x 3 1/2" x 3"
>> Vertical or Horizontal Mounting
>> Includes Locking Key and Mounting Hardware
Part #: BTG-RK
Recommended Thermocouple Sensors
Lascar Type K Thermocouple with 4" SS Probe
>> Range: 0°C to 400°C (32°F to 752°F)
>> Cable Length: 1.5 Meters
>> Includes Yellow Type K Connector

Part #: EL-TC-K4-15

6ft. Beaded Type J Thermocouple w/ Connector
>> Teflon-Insulated Probe with Subminiature Connector
>> Temperature Range: 0°C to 250°C
>> Accuracy of Probe: ±2.2°C (Overall Accuracy Dependant on Logger)
>> Includes 6ft of Insulated 30 AWG Wire Wound on Spool Caddy
Quantity Price Each
1 - 9  
10+  
Part #: TC6-J
6ft. Beaded Type K Thermocouple w/ Connector
>> Glass-Braid Insulated Probe with Subminiature Connector
>> Temperature Range: 0°C to 482°C
>> Accuracy of Probe: ±2.2°C at 285°C to 482°C (Overall Accuracy Dependant on Logger)
>> Includes 6ft of Insulated 30 AWG Wire Wound on Spool Caddy
Quantity Price Each
1 - 9  
10+  
Part #: TC6-K
6ft. Beaded Type T Thermocouple w/ Connector
>> Teflon Insulated Probe with Subminiature Connector
>> Temperature Range: -200°C to 180°C
>> Accuracy of Probe: ±1.0°C at -65°C to 130°C (Overall Accuracy Dependant on Logger)
>> Includes 6ft of Insulated 30 AWG Wire Wound on Spool Caddy
Quantity Price Each
1 - 9  
10+  
Part #: TC6-T
Miniature Thermocouple Connector Plug
>> Male Miniature Connector Plug with 2 Prongs
>> Color-Coded: Yellow (Type K), Blue (Type T), Black (Type J)
>> Polarized Pins & Connector Body
>> Rated: -58°F to 410°F (-50°C to 210°C)
>> Suitable for Wire Diameters up to 22 AWG (0.025"D)
>> Available in Type J, K or T
Type:
Miniature Thermocouple Connector Jack Miniature Thermocouple Connector Jack
>> Female Flat Pin Miniature Connector
>> Color-Coded: Yellow (Type K), Blue (Type T), Black (Type J)
>> Polarized Pins & Connector Body
>> Rated: -58°F to 410°F (-50°C to 210°C)
>> Suitable for Wire Diameters up to 22 AWG (0.025"D)
Type:

Small Selection of Thermocouples Available

EasyLog USB Thermocouple Logger w/ LCD Display Applications

  • Extreme Temperature Monitoring including Cryogenics and Industrial Ovens
  • Monitor, Analyze and Log Building and Warehouse Environmental Conditions
  • Monitor and Record Heating, Air Conditioning Equipment (HVAC)

Lascar EasyLog EL-WIN-USB Software

The EasyLog Software is available as a free download and with the purchase of a Lascar USB Data Logger. The software allows for the configuration of each logger, download of recorded data and data analysis. This windows PC software is compatible with Windows XP, Vista & 7 (both 32 and 64 Bit Versions). A step-by-step software installation guide is available.

Version 6 of the software includes and updated user interface, graphing support for the USB Event (#EL-USB-5) Data Logger, and large data sets.

Easylog Software Video Tutorials

How to Download the Data from a Lascar USB Data Logger

Lascar Electronics Easylog Software and Data Logger Setup Demo