Electro Industries/GaugeTech Traceable Revenue Meter, Datalogger with WiFi
>> 0.2% Accuracy Class Revenue Certifiable Energy with KYZ Output and Demand Submeter
>> Utility Demand Profiles wtih User-Configured Block Window or Rolling Window Demand
>> Utility Grade Test Pulse for Revenue Metering and Accuracy Verification/Certification
>> Multifunction Measurements, 3 Line 0.56" LED Display and % of Lead Bar for Analog Perception
>> Standard RS485 (Modbus and DNP 3.0) and IrDA Port (PDA or Pocket PC)
>> 2 MB of Storage for Data Logging Historical Trends, Limit Alarms and Sequence of Events
>> Optional WiFi/RJ45 Ethernet Communications Connection and IP Address Assignment
>> Energy Usage Data Collection and Analysis Using Optional E-Billing EXT™ Software
>> Includes CommunicatorEXT 3.0 for Windows Single-User License Software
The Shark Products is Built to Order and Can Have a Lengthy Lead Time to Delivery.
This product Line is NOT RETURNABLE FOR CREDIT Unless There Are Defects Due to Manufacturer Error.
NOTE: Large Quantity Discounts Available!
Specifications
Voltage Inputs | Universal Voltage Input Line to Neutral: 20 to 576 Volts Line to Line: 0 to 721 Volts Input Withstand Capability: Meets IEEE C37.90.1 (Surge Withstand Capability) Programmable Voltage Range: Any PT Ratio Supports: 3 Element Wye, 2.5 Element Wye, 2 Element Delta, 4 Wire Delta Systems Burden: 0.14VA at 120 Volts; 0.36VA Per Phase Max at 600 Volts Input Impedance: 1M Ohm/Phase Pickup Voltage: 20 Volts AC Connection: 7 pin 0.400" Screw Terminal Block Fault Withstand: Meets IEEE C37.90.1 (Surge Withstand Capability) |
Current Inputs | Class 10: 5 Amp Nominal, 10 Amp Maximum Class 2: 1 Amp Nominal, 2 Amp Secondary Programmable Current: Any CT Ratio Burden: 0.005VA per Phase Max at 11 Amps Pickup Current: 5mA (Class 10); 1mA (Class 2) Connections: Screw Terminal - #6-32 Screws Fault Withstand: Meets IEEE C37.90.1 (Surge Withstand Capability) |
Accuracy (Class 10) |
Voltage - Line to Neutral: 0.1% of Reading Voltage - Line to Line: 0.1% of Reading Current: 0.1% of Reading +/- Watts: 0.2% of Reading +/- Wh: 0.2% of Reading +/- VARs: 0.2% of Reading +/- VARh: 0.2% of Reading VA: 0.2% of Reading VAh: 0.2% of Reading PF: 0.2% of Reading Frequency: ±0.03 Hz %THD: ±5.0% %Load Bar: ±1 Segment |
Isolation | Inputs/Outputs are Galvanically Isolated to 2500 Volts AC |
KYZ Pulse | Type: Form C Contact Resistance: 35 Ohms Max Peak Voltage: 350 Volts DC Continuous Load Current: 120 mA Peak Load Current: 350 mA (10ms) Off State Leakage Current: 1uA (@350 VDC) |
Sensing Method | >> RMS >> Sample Over 400 Readings/Cycle on All Channels Simultaneously |
Logging | >> Historical Trends >> System Events >> Limit/Alarms |
Update Rate | Watts, VAR and VA: 100msec @ 60 Hz - Every 6 Cycles All Other Parameters: 1 Second @ 60 Hz - Every 60 Cycles |
Communication Ports | Number of Ports: 2 Type: RS485 (Modbus ASCII, Modbs RTU and DNP 3.0 Protocols); Optical IrDA Baud Rate: 9,600 to 57,600 Port Address: 1 to 247 Bit, Parity: 8 Bit, No Parity |
Wireless Ethernet | >> 802.11b Wireless, WiFi or 10BaseT Ethernet (RJ45) >> 128 bit WEP Encryption: 128 bit Wireless Security >> Modbus TCP Protocol |
Standards Compliance | CE IEC 687 (0.2% Accuracy) ANSI C12.20 (0.2% Accuracy) ANSI (IEEE) C37.90.1 Surge Withstand ANSI C62.41 (Burst) IEC1000-4-2 - ESD IEC1000-4-3 - Radiated Immunity IEC1000-4-4 - Fast Transient IEC1000-4-5 - Surge Immunity Faceplate Rating: NEMA 12 (Water Resistant) |
Power Supply | Burden: 16 VA Max. Type: 90 to 400 Volts AC and 100 to 370 Volts DC - Universal AC/DC Supply |
Operating Conditions | Temperature: -20°C to 70°C Humidity: 0 to 95% RH Non-Condensing |
Storage Conditions | Temperature: -20°C to 70°C Humidity: 0 to 95% RH Non-Condensing |
Dimensions | 7.9" x 7.5" x 3.1" (200.1mm x 191.3mm x 79mm) Antenna Length: 4.4" (111.8mm) |
Weight | 64 oz. (4.0 lbs) |
Part # | EIG-SHARK200-S-50-2-485 |
Base Price | |
Frequency | |
Current Input | |
Communications |
![]() |
Standard NIST DC Voltage Calibration Service >> 1 Point (per Channel) Offset Calibration
>> Traceable to NIST >> Certificate Supplied >> Note: 3 to 5 Day Lead Time for All Calibration Orders |
Part #: CAL-NIST-DCVOLT |
Optional CTs
A Shorting Block (# EL-SB-6TC) is Required with CTs.
![]() |
EIG 100/5A Split Core CT >> Measurement Range: 0 to 100 Amps
>> Output: 5 Amp >> Inside Window Diameter: 0.84" x 2.0" |
Part #: EIG-1SP-100-00 |
![]() |
EIG 200/5A Split Core CT >> Measurement Range: 0 to 200 Amps
>> Output: 5 Amp >> Inside Window Diameter: 0.84" x 2.0" |
Part #: EIG-1SP-200-00 |
![]() |
EIG 400/5A Split Core CT >> Measurement Range: 0 to 400 Amps
>> Output: 5 Amp >> Inside Window Diameter: 2.19" x 3.25" |
Part #: EIG-1SP-400-00 |
![]() |
EIG 600/5A Split Core CT >> Measurement Range: 0 to 600 Amps
>> Output: 5 Amp >> Inside Window Diameter: 2.19" x 3.25" |
Part #: EIG-3SP-600-00 |
![]() |
EIG 800/5A Split Core CT >> Measurement Range: 0 to 800 Amps
>> Output: 5 Amp >> Inside Window Diameter: 2.19" x 3.25" |
Part #: EIG-3SP-800-00 |
![]() |
EIG 1200/5A Split Core CT >> Measurement Range: 0 to 1200 Amps
>> Output: 5 Amp >> Inside Window Diameter: 2.88" x 4.25" |
Part #: EIG-5SP-1200-00 |
![]() |
EIG 1600/5A Split Core CT >> Measurement Range: 0 to 1600 Amps
>> Output: 5 Amp >> Inside Window Diameter: 2.88" x 6.25" |
Part #: EIG-7SP-1600-00 |
![]() |
EIG 2000/5A Split Core CT >> Measurement Range: 0 to 2000 Amps
>> Output: 5 Amp >> Inside Window Diameter: 4.00" x 7.50" |
Part #: EIG-91SP-2000-00 |
![]() |
EIG 3000/5A Split Core CT >> Measurement Range: 0 to 3000 Amps
>> Output: 5 Amp >> Inside Window Diameter: 4.00" x 7.50" |
Part #: EIG-91SP-3000-00 |
![]() |
EIG 4000/5A Split Core CT >> Measurement Range: 0 to 4000 Amps
>> Output: 5 Amp >> Inside Window Diameter: 4.00" x 7.50" |
Part #: EIG-91SP-4000-00 |
Shorting Block - Required | ||
![]() |
6 Pole CT Shorting Block with Protective Cover >> 600 Volt Rating
>> 50 Amp Current Rating >> 4 Pole Configuration >> 10 AWG Max Wire Range >> Hinged Clear Plastic Cover w/ Marking Plate >> Brass Terminals Allow Up to 1/2" Wide Connectors >> UL Recognized |
Part #: EIG-SB-6TC |
Documentation (pdf)
Shark 200S Quick Start Guide (130 KB .pdf)
Shark 200S User Manual (2 MB .pdf)