Error
  • JUser: :_load: Unable to load user with ID: 42

Compact Water Resistant Temperature Data Logger with External Sensor

TandD Temp Logger w/ Infrared or Optical Communications Options

>> Measure and Record Temperature Readings Using External Sensor
>> -60°C to 155°C Temperature Measurement Range With 0.3°C Accuracy Over -20°C to 80°
C Range
>> Battery-Powered with 4 Year Battery Life
>> Stores up to 16,000 Sample Readings on Logger and Data Collector Downloads Data
>> Blinking Visual LED Indicator When Upper or Lower Alarm Thresholds are Met
>> Measurement Sampling Rate of 1 Second to 60 Minutes
>> LCD Display Shows Current Temperature Readings, Battery Level, Storage Level and Alarm Status 
>> Includes Flourpolymer-Coated Sensor (#TR-5106), Battery, Tube, Strap and User Manual

TandD Optical Temperature Data Logger Specifications

Measurement Channel 1 External Temperature Channel
Temperature Range: -60°C to 155°C
Accuracy: ±0.3°C (-20°C to 80°C); ±0.5°C (-40°C to -20°C); ±0.5°C (80°C to -110°C); ±1.0°C (-60°C to -40°C); ±1.0°C (110°C to 155°C)
Resolution: 0.1°C
Data Storage Capacity 16,000 Samples/Readings
Recording Start Method Immediate or Programmed
Recording Mode Endless Loop or One-Time
Recording Interval 1,2,5,10,15,20,30 sec / 1,2,5,10,15,20,30,60 min
LCD Display Current Temperature, Recording Status, Recording Mode, Infrared Communication Status, Battery Life Warning, Memory Full, Sensor Unconnected, Measurement Range Exceeded, Upper / Lower Limit Over and Unit of Measurement (°F or °C)
Communication Interfaces Optical or Infrared Communication
Infrared Type: IrPHY 1.2 Low Power
Communication Interfaces At Full Storage Capacity Using Compatible Data Collectors
Optical: 24 Seconds (w/ #TR-57DCI); 20 Seconds (w/ #TR-50U); 160 Seconds (w/ #TR-57U)
Infrared: 55 Seconds (w/ #TR-57DCI)
Alarm Visual Flashing LED Indicator for Setting Upper and Lower Limits
Power 1 LS14250 Lithium Battery
Battery Life Approx. 4 Years (2 Years if Infrared Communications Selected)
(Depends on measurement environment, recording interval and battery performance)
Standards Compliance IP64 (Splash Resistant)
Weight 55g with Battery (without Sensor)
Dimensions 62mm x 47mm x 19mm

Temperature Data Logger with External Probe Temperature Data Logger with External Probe
>> Single Channel Temp Data Logger with External Sensor
>> Measurement Range: -60°C to +155°C
>> 4-Year Battery Life
>> Includes Sensor, Battery and User Manual
>> Requires Communication and Software Set (#TR-57DCI or #TR-50U)
Part #: TR-52I
Optional NIST Calibration Service
Standard NIST Temperature Calibration Service Standard NIST Temperature Calibration Service
>> 1 Point Offset Calibration
>> Traceable to NIST
>> Certificate Supplied
>> Note: 3 to 5 Day Lead Time for All Calibration Orders


Part #: CAL-NIST-TEMP

Optional Accessories

TandD Temperature Sensor Extension Cable
>> 3.0 Meter (120") Extension Cable
>> An Error Factor of ±0.3°C @ Normal Temperatures and ±0.5°C @ -50°C is Expected for Each Length of Extension Cable Used. Calibration Service is Recommended if Adding More Than 1.
>> Compatible with TandD External Temperature Sensors
Part #: TR-2C30
Wall Mount for RTR-5 and RTR-500 Series Loggers Wall Mount for RTR-5 and RTR-500 Series Loggers
>> Material: Polycarbonate
>> Dimension: 66mm x 70mm x 24.7mm
>> Screw Holes: (2) - 4.2mm
>> Includes (2) Lock Screws and (1) Double-Sided Adhesive Tape
>> NOTE: Cracks May Develop If Exposed to Strong Impact at temperature of -30C or Less
Part #: TR-05K3
Maintenance Set Maintenance Set
>> Includes Rubber Packing, Silica Gel, Double-Sided Adhesive Tape, and Lock Screws
Part #: TR-00P1
Maintenance Set Battery Set for Low-Temperature Use
>> Includes Lithium battery, Tube and Maintenance Set
Part #: TR-11P2
Locking Protective Wall Cover Locking Protective Wall Cover
>> Clear Plastic
>> Dimension: 3 7/8" x 3 1/2" x 2 1/2"
>> Vertical or Horizontal Mounting
>> Includes Locking Key and Mounting Hardware
Part #: BTG-EK

Optional Sensors

Flexible 24" Temperature Sensor
>> Flexible Fluoropolymer Coated Sensor with Excellent Chemical and Corrosion Resistance
>> Cable Length: 0.6 Meters (24 Inches)
>> Temperature Range:-60°C to 155°C (-76°F to 311°F)
>> Temperature Accuracy: ±0.3°C Avg @ -20°C to 80°C
>> Sensor Response Time: 15 Sec (Air); 2 Sec (Agitated Water)
>> Compatible with: TR-52, RTR-52, RTR-502 Data Loggers
Part #: TR-5106
Flexible 1.8" Temperature Sensor
>> Flexible Fluoropolymer Coated Sensor with Excellent Chemical and Corrosion Resistance
>> Cable Length: 45 mm (1.8 Inches)
>> Range: 60°C to 155°C (-76°F to 311°F)
>> Accuracy: ±0.3°C Avg @ -20°C to 80°C Range
>> Response Time: 15 Seconds (Air); 2 Seconds (Agitated Water)
>> Compatible with TandD TR-52, RTR-52 and RTR-502 Data Loggers
Part #: TR-5101
Stainless Steel Temperature Probe
>> 7.2" Stainless Steel Probe
>> Cable Length: 2 Meters (80 Inches)
>> Range: -60°C to 155°C (-76°F to 311°F)
>> Accuracy: ±0.3°C Avg @ -20°C to 80°C Range
>> Response Time: 36 Seconds (Air); 7 Seconds (Agitated Water)
>> Compatible with TandD TR-52, RTR-52, RTR-502 Data Loggers
Part #: TR-5220
Stainless Steel Temperature Probe w/ Tapered End
>> 2.7" (70mm) Stainless Steel Tapered End Probe
>> Cable Length: 2 Meters (80 Inches)
>> Range: -60°C to 155°C (-76°F to 311°F)
>> Accuracy: ±0.3°C Avg @ -20°C to 80°C Range
>> Response Time: 12 Seconds (Air); 2 Seconds (Agitated Water)
>> Compatible with TandD TR-52, RTR-52, RTR-502 Data Loggers
Part #: TR-5320
Stainless Steel Temperature Probe w/ Pointed End
>> 2.7" (70mm) Stainless Steel Pointed End Probe
>> Cable Length: 2 Meters (80 Inches)
>> Range: -60°C to 155°C (-76°F to 311°F)
>> Accuracy: ±0.3°C Avg @ -20°C to 80°C Range
>> Response Time: 12 Seconds (Air); 2 Seconds (Agitated Water)
>> Compatible with TandD TR-52, RTR-52, RTR-502 Data Loggers
Part #: TR-5420
Water Immersible Temperature Sensor
>> 3.9" Stainless steel Probe Protected with Fluoropolymer Coated Mold for Excellent Chemical and Corrosion Resistance
>> Cable Length: 3 Meters (120 Inches)
>> Range: -60°C to 155°C (-76°F to 311°F)
>> Accuracy: ±0.3°C Avg @ -20°C to 80°C Range
>> Response Time: 120 Seconds (Air); 6 Seconds (Agitated Water)
>> Compatible with TandD TR-52, RTR-52, RTR-502 Data Loggers
Part #: TR-5530

Data Collectors - 1 Required

Infrared Communications Data Collector Infrared Communications Data Collector
>> Downloads Data onto Collector Using Infrared Communications Port
>> Stored Data is Downloaded to PC with USB Cable
>> Includes USB Cable, T&D Recorder for Windows Software and User Manual
Part #: TR-57DCI
Optical Communications Set Optical Communications Set
>> Downloads Data onto Collector Using Optical Communications Port
>> Stored Data is Downloaded to PC with USB Cable
>> Includes USB Cable, T&D Recorder for Windows Software and User Manual
Part #: TR-50U2

Documentation

TR-52I User Manual (.pdf)
TandD Recorder for Windows Software User Manual (.pdf)