Supco Strip Chart Recorders - DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR | DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR

Supco Strip Chart Recorders

 

The Strip Chart Recorder is designed to record the output of 4 to 20 mA loop transmitters and voltage output transducers. The chart recorder comes with a plug in screw type connector to facilitate connection to current loops. The recorder uses a single pen and records the DC voltage and current information on a 20 foot long, 4 and 3/4" wide strip chart. Power is supplied through a 120 VAC 50/60 Hz plug-in adapter.

NOTE: Large Quantity Discounts Are Available!

Strip Recorder Features

  • +12 Volts DC for mobile applications
  • User selectable Delay / No Delay
  • Battery Backup up to 48 Hours
  • Probes are Field Interchangeable and can be Extended
  • Optional NIST Certification Available

Strip Chart Recorder Specifications

Operating Temperature Range 32°F to 120°F (0°C to 50°C)
Storage Temperature 0°F to 120°F (-18°C to 50°C)
Primary Power 115 VAC, 50/60 Hz Adapter
(220-240 VAC, 50Hz optional)
Backup Power 8 AA Alkaline Batteries (Not Supplied)
Alternative Power 12 Volt Vehicle Operation with Optional Adapter
Accuracy 0 to 5.00 Volts +/- 0.01 Volt
0 to 100 mV +/- 1 mV 
0 to 20 mA +/- 0.1 mA
4 to 30 mA +/- 0.1 mA
Chart Strip Chart (20' x 4 3/4")
Chart Speeds 1/4 inch/hr (1/2 cm/hr) 
1 inch/hr (2 cm/hr) 
2 inches/hr (4 cm/hr) 
4 inches/hr (8 cm/hr)
8 inches/hr (16 cm/hr) 
1/4 inch/min (1/2cm/min) 
1/2 inch/min (1 cm/min) 
1 inch/min (2 cm/min) 
2 inch/min (4 cm/min)
Chart Speed Accuracy ±1%
Display Alphanumeric LCD
DC Current Alarm Range 0 to 20 mA
DC Voltage Alarm Range 0 to 5 Volts
Alarm Delay Range No Delay, 10 min., 30 min., 1 hr or 2 hr
Remote Alarm Connection Normally Open Contact 48 VAC/DC, 0.1 Amp Dry
Mounting Vertical or Horizontal, Free Standing ro Wall Mounted
Dimensions 9.25" x 7.25" x 2.0"
Weight 2.5 lbs.
Power Consumption 3.5 Watts Max.

Strip Recorder Applications

  • HVAC/R
  • Laboratory Testing
  • Environmental Studies
Description Part Number
Supco Strip Chart 4-20mA Recorder SR4-20
Optional Recorder Accessories
Black Replacement Pen for Supco Chart Recorders CRPEN
Red Replacement Pen for Supco Chart Recorders CRPENR
Blue Replacement Pen for Supco Chart Recorders CRPENB
115 to 120 VAC Power Adapter (USA) CRT
220VAC Power Adapter (Europe) CRT220
12 Volt DC (240VAC) Power Adapter (UK) CRT220UK
Strip Chart Paper
Strip Chart Paper for Supco Strip Chart Recorders (US Measurement Version) SCR11
Strip Chart Paper for Supco Strip Chart Recorders (Metric Measurement Version) SCR12
Optional NIST Calibration
Standard NIST DC Voltage Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders CAL-NIST-DCVOLT
Standard NIST 4-20mA Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders CAL-NIST-420MA