Powerscout Energy & Power Meters - DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR | DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR

Powerscout Energy & Power Meters

>> 3 Channel Meter Supports Full Range of Splilt-Core or RoCoil Rogowski-Style CTs (Sold Separately)
>> Outputs to a RS-422/485 Serial Communication Supporting BACnet, Modbus or Pulse Only Modes
>> Patented PhaseChek™ LED Indicators Guarantee Correct CT Orientation
>> US and Int'l Versions Available w/ Colored Voltage Leads
>> Requires Powerscout Communications Package (#PS-COMPAK-USB) & Current Transformers (CTs)
The PowerScout 3+ Power Meter can measure over 50 energy and power parameters. This single-point 3-phase power meter features PhaseChek™ circuitry, LED indicators, line-powered 60 to 600 volt Phase-Phase power supply and RS-422/485 serial connection. The Dent PowerScout 3+ supports BACnet and Modbus Industry-Standard Protocols. In addition, the power meter has a "Pulse Output Mode" and when connected to a pulse data logger will log pulses based on accumulated values(s) such as system kWh, kVARh and kVAh. A single BACnet client can support up to 127 Powerscout 3+ and a Modbus Control System can support up to 254 meters.

Specifications for PowerScout Power Meter

Service Types Single Phase
Three Phase-4 Wire (Wye)
Three Phase-Three Wire (Delta)
Outputs Pulse
BACnet (Master Slave Token Passing Protocol)
Modbus
Voltage Channels: 3
Line-to-Neutral: 80 to 346 Volts AC
Line-to-Line: 600 Volts
Safety Rating: CAT III
Current Channels: 3
Measurement Range: 0 to 5,000+ Amps
Note: Range is Dependant upon Current Transducer
Max Current Input 175% of Current Transducer Rating
Measurement Type True RMS using High Speed Digital Signal Processing (DSP)
Line Frequency 50/60/400 Hz
Waveform Sampling 12 kHz
Parameter Update 500 milliseconds
Measurements Volts, Amps, kW, kWh, kVAR, kVARh, Apparent Power Factor (aPF), Displacement Power Factor (dPF).
All Parameters for Each Phase and for System Total
Accuracy Better than 1% (<0.5% Typical) for V, A, kW,kVAR, kVA, PF
Resolution 0.01 Amp. 0.1 Volt, 0.01 Watt, 0.01 VAR, 0.01 VA, 0.01 Power Factor
LEDs Bi-Color LEDs (red and Green)
1 LED to Indicate Communication
3 LEDs for Correct phasing (PhaseChek - Green: Voltage & Current on Smae Phase - Red: incorrectly Wired)
2 Digital Channel Indicators
Pulse Output Open Collector
Max Current: 75 mA
Open Voltage: 40 Volt Max
NOTE: The pulse output is scaled by the same data scalar register (44062) as are the Modbus registers. For Example, When the data scalar is set to 3, each pulse will represent 0.1 kWh, 0.1 kVAh and 0.1 kVARh
Communications Output: Pulse, Modbus or BACnet over RS-485
Distance: 1200 Meters @100K bits/second Data Range (Max)
Baud Rate: 9600 (Modbus Default), 19200, 38400, 57600, 76800 (BACnet Default), 115200
Data Bits: 8
Parity: None, Even and Odd
Stop Bit: 2, 1 and 0
Data Formats: Modbus Protocol OR BACnet (MS/TP) Protocol
Power: From L1 Phase to L2 Phase. 80 to 600 Volts AC CAT III 50/60Hz 70 mA Max. Non-User Replaceable 0.5 Amp Internal Fuse Protection
Operating Range Temperature: -7C to 60C (-20F to 140F)
Humidity: 5% to 95% RH
Enclosure ABS Plastic, 94-V0 Flammability Rating
Software Compatibility Windows 7 (32 or 64 Bit), Vista (32 or 64 Bit) and XP
Weight 357 grams (12.6 oz.) - Excluding CTs
Dimensions 21.8cm x 5.8cm x 4.0cm (8.6" x 5.8"x 1.6")

 

Part # PS3P-US
Base Price (CTs Sold Separately)
Transformer & Voltage Lead Colors  

 

Powerscout Communications Package Powerscout Communications Package
>> Compatible with Powerscout 3+ and Powerscout 18
>> Includes Viewpoint Software, USB-RS485 Adapter Assembly and User Manual
Part #: PS-COMPAK-USB