Telaire 7001 Carbon Dioxide (CO2) Monitor - DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR | DATA LOGGER MALAYSIA OFFICIAL DISTRIBUTOR

Telaire 7001 Carbon Dioxide (CO2) Monitor

 

The hand held Telaire 7001 Monitor measures Carbon Dioxide and Temperature. The monitor provides stable, highly accurate readings with its patented dual beam NDIR technology. The CO2 Monitor features a 0-4 Volt output, large LCD display with push button interface, quick adjustments for altitude correction, simple toggling between °C and °F temperature readings and runs for 70+ hours on four AA alkaline batteries or continuously with the supplied power adapter. The sensor has a CO2 range suitable for virtually any building (0-10,000 ppm). Click here for more on monitoring building air.

The CO2 Monitor is also available with a Data Logger as a Kit.

Telaire 7001 CO2 Data Logger Kit

>> (1) Telaire 7001 Carbon Dioxide Monitor (#7001)
>> (1) 4 Channel Data Loggers (#U12-012) or (#U12-013)
>> (1) Cable Connecting Logger to Monitor (#CABLE-C02)
>> (1) HOBOware Lite Software (#BWH-LITE)

Carbon Dioxide Monitor Features

  • Monitor Carbon Dioxide and Temperature Readings
  • Provides a 0 to 4 Volt Output
  • 0 to 10,000 ppm Carbon Dioxide Measurement on Display
  • 0-4,000 ppm Carbon Dioxide Measurement Output
  • Available as a Kit with Data Logger

Carbon Dioxide Monitor Specifications

Performance CO2 Channel
Measurement Range 0-4,000 ppm Voltage Output
0-10,000 ppm Display
Pressure Dependence 0.13% of reading per mm Hg
(Corrected via user input for elevation)
Sensitivity ± 1 ppm
Repeatability ± 20 ppm
Temperature Dependence ± 0.1% of reading per °C; or ± 2 ppm per °C;
whichever is greater, referenced to 25°C;
Accuracy ± 50 ppm or 5% of reading, whichever is greater
Annual Drift ± 20 ppm typical
Response Time < 60 seconds for 90% of step change
Warm-Up Time < 60 seconds at 22°C
Operating Conditions Temperature:32°F to 122°F (0° to 50°C)
Humidity: 0-95% RH, Non-Condensing
Storage Temperatures -40°F to 140°F (-40°C to 60°C)
Calibration Interval 12 months, offset adjustment using single gas at 0-1000 ppm CO2. Factory calibration available
Temperature Channel
Temperature Range Voltage Output: 32°F to 104°F (0°C to 40°C)
Display: 32°F to 122°F (0°C to 50°C)
Display Resolution 0.1°F (0.1°C)
Display Options °F, °C, or Off. Set with Panel Button
Accuracy ± 2°F (± 1°C)
Response Time 20-30 minutes
(Case must Equilibrate with Environment)
Calibration Interval 12 months, offset adjustment using temperature standard at 50°F to 86°F (10°C to 30°C).
Full factory calibration available
Other Specifications
Method Dual Beam Absorption Infrared™
Sample Method Diffusion or flow through (50 - 100 ml/min)
Warranty 18 months parts and labor
Output
Analog CO2: 0-4 VDC, 1mV/ppm (4,000 ppm max)
Temperature: 0-4 VDC linear, 32°F to 104°F (0°C to 40°C)
Output Impedance 100 Ohms
Wiring Connection Via RJ-45 to DB9 Serial Port Cable
Display LCD with independent CO2/ temp readings (panel buttons set elevation, °F/°C, calibration functions)
Power Supply
Battery Type Four AA Alkaline Batteries (Not Included)
Battery Operation 80 Hours (alkaline)
External 6 VDC from external AC/DC adapter (included)
Power Requirements 100 mA Peak, 20 mA average from 6V Certification

 

Description Part Number
Telaire 7001 Carbon Dioxide (CO2) Monitor TELAIRE-7001
Telaire CO2 Kit (Includes Telaire Monitor, HOBO U12-012 Logger, Monitor to Logger Cable and HOBOware Lite Software) 7001D-KIT
Telaire CO2 Kit (Includes Telaire Monitor, HOBO U12-013 Logger, Monitor to Logger Cable and HOBOware Lite Software) 7001D-KIT2
The CO2 Monitor is compatible with the following HOBO data loggers
HOBO U12 4 Channel External Input Data Logger HOBO U12 4 Channel External Input Data Logger
>> 4 input Channels Accepting External Sensor Probes
>> Store 43,000 Measured Readings
>> 0 to 2.5 Volts DC Measurement Range
>> Requires HOBOWare Software (Pro or Lite)
>> Includes Mounting Kit, Hook and Loop Wire, Tie Wrap and Screws
Quantity Price Each
1 - 9  
10+  
Part #: U12-006
HOBO U12 Temp/RH/Light/External Data Logger HOBO U12 Temp/RH/Light/External Data Logger
>> Temperature, Humidity, Light and 1 Analog Input Channel
>> Stores up to 43,000 Measure Readings
>> Requires HOBOWare Software (Pro or Lite)
>> Includes Mounting Kit w/ Magnet, Hook & Loop Tape, Tie-Wraps and Mounting Screws
Quantity Price Each
1 - 9  
10+  
Part #: U12-012
HOBO U12 Temp/RH/2x External Data Logger HOBO U12 Temp/RH/2x External Data Logger
>> Temperature, Humidity and 2 Analog Input Channels
>> Stores up to 43,000 Measured Readings
>> Requires HOBOWare Software (Pro or Lite)
>> Includes Mounting Kit w/ Magnet, Hook & Loop Tape, Tie-Wraps and Mounting Screws
Quantity Price Each
1 - 9  
10+  
Part #: U12-013
HOBO Data Logger to CO2 Monitor Cables - Required
Telaire CO2 Monitor to Data Logger Cable CABLE-CO2
The CO2 Monitor is compatible with the following TandD data loggers
TandD Wireless Voltage/Pulse Logger RVR-52A
TandD 2 Channel Voltage Logger VR-71
TandD Data Logger to CO2 Monitor Cables - Required
CO2 and Temperature Output Cable with 2 Leads 2070
HOBO Data Logger Software Kits
HOBOware Lite Software Kit for Windows/Mac (includes Software and Cable) BHW-LITE-CD
HOBOware Pro Software Kit for Windows/Mac (includes Software and Cable) BHW-PRO-CD
Optional Accessories
AA Batteries (Lithium) 4 Pack HWSB-LI

Using the Telaire 7001 with a Data Logger

The Telaire 7001 Carbon Dioxide Monitor also can be connected to a data logger with an external input to measure and record carbon dioxide levels. An interface cable (#CABLE-CO2) connects the Telaire 7001 to the HOBO data logger's external input. The Data loggers are sold separately.

Data Logging Notes: A HOBO data logger can be used with the Telaire 7001 to log CO2 levels over the range of 0 to 2500 ppm with 10 ppm resolution. The HOBOware Lite software will display the data as voltage readings from 0 to 2.5 volts, with every 0.001 volt corresponding to 1 ppm. The Telaire 7001 can actually measure and display values up to 10,000 ppm, but any value greater than 2500 ppm will output a voltage over the HOBO's 2.5 volt input range. This will cause all channels to measure incorrectly until the value drops back below 2500 ppm.

What is a good CO2 level?

There is no single 'good' CO2 level. CO2 is not directly harmful unless concentrations get very high (i.e. above 15,000 ppm). An appropriate indoor CO2 level is determined based on the ventilation requirements established by ASHRAE and the outside CO2 levels. It is the difference of these two values which correlates to the ventilation rate. Take for example an indoor level of 1100 ppm (measured while occupancy is steady). Assuming an outside level of 400 ppm the difference between indoor and outdoor levels is 700 ppm. This equates to 15 cfm per person. For more information on this conversion or additional examples use the Telaire Ventilation calculator (comes with the Telaire 7001).