SmartReader Plus 7 Data Logger
The SmartReader Plus 7 data logger records process signals easily. With seven input channels it is
ideal for monitoring (through commercially available transducers) a wide variety of measurement parameters. All process signals can be displayed in their own engineering units using the simple equation editor in the TrendReader Software.
Required with SmartReader Plus 7 Data Logger
>> TrendReader 2 software
Required for Ethernet Connectivity
>> TrendReader 2 Software with USB Cable Kit (#TR2-USB)
>> Read the Networking and Remote Communications Guide
SmartReader Plus 7 Logger Features
- Monitoring wind speed, flow, tank level, pressure, current, voltage
- SCADA troubleshooting
SmartReader Plus 7 Logger Specifications
| General Specifications | |
|---|---|
| Channels | Eight: One internal thermistor and 7 analog inputs |
| Memory Size | Available in 32 KB (21,500 readings), 128 K (87,000 readings) or 1.5 MB (1,048,000 readings) versions |
| Size | 107 x 74 x 22 mm. (4.2” x 2.9” x 0.9”) |
| Weight | 110 grams (3.75 ounces) |
| Case Material | Noryl Plastic |
| External Connector | Removable screw-type terminal strip with Common (-) connection |
| Operating Limits | -40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing) |
| Clock Accuracy | ±2 seconds per day |
| Battery | 3.6 volt Lithium, 1 Amp-Hour |
| Battery Life | 10 year warranty (under normal use), factory replaceable |
| Power Consumption | 5 to 10 microamps (continuous) |
| Sampling Methods | 1. Continuous (First-in, First-out – not available with sample rates faster than 8 seconds) 2. Stop when full (Fill-then-stop) |
| Sampling Rates | User selectable rates from 25 per second to 1 reading every 8 hrs. (BP-101 Battery Pack or PS-201 Power Supply required for sample rates faster than 8 seconds) |
| Resolution | 12 bit (1 part in 4,096) |
| Mounting | Magnetic backing or locking eyelet |
| Software Compatiblity | Windows 3.1, 95, 98, 2000, ME, NT, XP, Vista (32-bit), Windows 7 (32-bit and 64-bit) |
| Product Approvals | Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets radiated and conducted emission require ments for the Interference Causing Equipment Standard f or Digital Apparatus of Industry Canada (ICES-003). IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE) |
| Resistance to X-Rays | Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport x-ray machine). Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5” |
| Input Impedance for Analog Input Channels | |
|---|---|
| Input Type | Input Impedance |
| 0 to 2.5 volts DC | Greater than 1M ohm |
| 0 to 5.0 volts DC | Greater than 1M ohm |
| 0 to 10.0 volts DC | Greater than 1M ohm |
| 0 to 200 millivolts DC | Greater than 1M ohm |
| 0 to 25 milliamps DC | 20 Ohm |
| Description | Part Number | |||
| Standard Models | ||||
| SmartReader Plus 7 32KB, 8-channels: one temp, seven channels of mixed voltage/current | SRP-007 | |||
| SmartReader Plus 7 128KB, 8-channels: one temp, seven channels of mixed voltage/current | SRP-007-128K | |||
| SmartReader Plus 7 1.5MB, 8-channels: one temp, seven channels of mixed voltage/current | SRP-007-1-5M | |||
| 0-25mA Versions | ||||
| SmartReader Plus 7 32KB, 8-channels: one temp, seven channels 0-25mA | SRP-007-25MA | |||
| SmartReader Plus 7 128KB, 8-channels: one temp, seven channels 0-25mA | SRP-007-25MA-128K | |||
| SmartReader Plus 7 1.5MB, 8-channels: one temp, seven channels 0-25mA | SRP-007-25MA-1-5M | |||
| 0 to 2.5 Volts Versions | ||||
| SmartReader Plus 7 32KB, 8-channels: one temp, seven channels 0-2.5vdc | SRP-007-0-2-5V | |||
| SmartReader Plus 7 128KB, 8-channels: one temp, seven channels 0-2.5vdc | SRP-007-0-2-5V-128K | |||
| 0 to 5 Volts Versions | ||||
| SmartReader Plus 7 32KB, 8-channels: one temp, seven channels 0-5vdc | SRP-007-0-5V | |||
| SmartReader Plus 7 32KB, 8-channels: one temp, seven channels 0-5VDC (Limited Quantity - 1 Available) | SRP-007-0-5V-32K--U-- | |||
| SmartReader Plus 7 128KB, 8-channels: one temp, seven channels 0-5vdc | SRP-007-0-5V-128K | |||
| SmartReader Plus 7 1.5MB, 8-channels: one temp, seven channels 0-5vdc | SRP-007-0-5V-1-5M | |||
| 0 to 10 Volts Versions | ||||
| SmartReader Plus 7 32KB, 8-channels: one temp, seven channels 0-10vdc | SRP-007-0-10V | |||
| SmartReader Plus 7 128KB, 8-channels: one temp, seven channels 0-10vdc | SRP-007-0-10V-128K | |||
| SmartReader Plus 7 1.5MB, 8-channels: one temp, seven channels 0-10vdc | SRP-007-0-10V-1-5M | |||
| Software Kit - 1 Required | ||||
| TrendReader 2 Software with RS-232 Cable (IC-101) and Manual for Smart Reader series | TR2-RS232 | |||
| TrendReader 2 Software with USB Interface Cable (IC-102) and Manual for Smart Reader series | TR2-USB | |||
| TrendReader 2 Software CD Only (interface cable and manual not included), for SmartReader Plus, Smart Reader, IAQ and OWL Loggers | TR2-Standard | |||
| AC Voltage Transducers | ||||
| Voltage Transducer for logging single phase, 120 Volt, 60 Hz electrical systems, for loggers with a 0-5 Volt channel | VT-1P | |||
| Voltage Transducer for logging three phases, 480 Volt, 60 Hz electrical systems, for loggers with a 0-5 Volt channel | VT-3P | |||
| Standard NIST Calibration Service | ||||
| Standard NIST Temperature Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders | CAL-NIST-TEMP | |||
| Standard NIST DC Voltage Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders | CAL-NIST-DCVOLT | |||
| Standard NIST 4-20mA Calibration (1 Point) Note: 3 to 5 Day Lead Time for All Calibration Orders | CAL-NIST-420MA | |||
| Optional Accessories | ||||
| Fast Sampling Battery Pack | BP-101 | |||
| Network/Fast Sampling Power Supply - 120V - North American Version | PS-201-NA | |||
| Network/Fast Sampling Power Supply - 220V - European Version | PS-201-EU | |||
| Extra RS-232 Interface Cable for SmartReader, SmartReader Plus and Nautilus loggers | IC-101 | |||
| USB Serial Adapter | CABLE-USB232 | |||
Fast Sampling with Battery Pack or External 120 Volt Power Supply
For sampling rates faster than once every 8 seconds, the Smart Reader Plus data loggers require the use of an external 120 volt power supply (#PS-201) or fast sampling battery pack (#BP-101).
The fast sampling battery pack has replaceable "AAA" batteries and 8" (20cm) cable attached, with a male stereo jack on the end. The stereo jack is plugged into the communication port on the Smart Reader Plus data logger.
The 120 Volt Power Supply is required when network length is greater than 50' , more than 3 loggers are on the network,