Error
  • JUser: :_load: Unable to load user with ID: 42

GL220 Midi Data Logger

>> 10 Channels for Voltage, Temp, Humidity (With Optional #B-530 Sensor), Pulse and Logic Measurements
>> 10ms (1 Channel), 20ms (2 Channels) and 100ms (All Channels Simultaneously) Sampling Rate
>> Isolated Input System Ensures Signals are Not Corrupted by Other Channels
>> 2GB Internal Data Storage w/ "Hot Swappable" USB Memory Device External Storage Option
>> Supports 20mV to 50 Volts, Thermocouple Type: R, S, B, K, E, T, J, N and W and 4 Pulse or Logic Channels with Optional Cable (#B-513)
>> 4.3" TFT Color LCD Display Shows Data in Waveform or Digital Format and Manage Logger Settings 
>> Ring Memory Function Allows for the Most Recent Data to be Saved to Internal Memory or External Device
>> Includes Software, 100 to 240 VAC Adapter and User Manual

GL220 Midi Logger Specifications

Number of Input Channels Analog: 10 Channels
External Analog Input 1 Channel: Trigger or Sampling Input
4 Channels: Logic or Pulse Input
External Analog Output Alarm Output 4 Channel
Measurement Ranges Voltage: 20, 50, 100, 200, 500mV; 1, 2, 5, 10, 20, 50V; 1 to 5 v FS
Temperature: Thermocouples Type K, J, E, T, R, S, B, N, W
Humidity: 0 to 100% (with Optional #B-530 Humidity Sensor)
Measurement Accuracy Voltage:
>> 0.1% Full Scale 
Type R Thermocouple:
>> 0°C ≤ TS ≤ 100°C: ±5.2°C
>> 100°C < TS ≤ 300°C: ±3.0°C
>> 300°C < TS ≤ 1600°C: ±(0.05 % of Rdg + 2.0°C)
Type S Thermocouple:
>> 0°C ≤ TS ≤ 100°C: ±5.2°C
>> 100°C < TS ≤ 300°C: ±3.0°C
>> 300°C < TS ≤ 1760°C: ±(0.05 % of Rdg + 2.0°C)
Type B Thermocouple:
>> 400°C ≤ TS ≤ 600°C: ±3.5°C
>> 600°C < TS ≤ 1820°C: ±(0.05% of Rdg + 2.0°C)
Type K Thermocouple:
>> -200°C ≤ TS ≤ -100°C: ±(0.05% of Rdg + 2.0°C)
>> -100°C < TS ≤ 1370°C: ±(0.05% of Rdg + 1.0°C)
Type E Thermocouple:
>> -200°C ≤ TS ≤ -100°C: ±(0.05% of Rdg + 2.0°C)
>> -100°C < TS ≤ 800°C: ±(0.05% of Rdg + 1.0°C)
Type T Thermocouple:
>> -200°C ≤ TS ≤ -100°C: ±(0.1% of Rdg + 1.5°C)
>> -100°C < TS ≤ 400°C: ±(0.1% of Rdg + 0.5°C)
Type J Thermocouple:
>> -200°C ≤ TS ≤ -100°C: ±2.7°C)
>> -100°C < TS ≤ 100°C: ±1.7°C)
>> 100°C < TS ≤ 1100°C: ±(0.05% of Rdg + 1.0 °C)
Type N Thermocouple:
>> 0°C ≤ TS ≤ 1300°C: ±(0.1% of Rdg + 1.0°C)
Type W Thermocouple:
>> 0°C ≤ TS ≤ 2000°C: ±(0.1% of Rdg + 1.5°C)
Reference Junction Compensation: ±0.5°C
Analog Input Filter Off, 2, 5, 10, 20, 40 (Moving Average in Selected Number)
Input Terminal Type Screw Terminal (M3 Screw)
Sampling Interval Sampling Interval up to 1 Hour.
The Fastest Sampling Rates and the Restrictions:
10ms (100 Times per Second): 1 Channel at a Time
20ms (50 Times per Second): 2 Channels at a Time
100ms (10 Times per Second): All Channels Simultaneously
Input Method Scans by the photo-MOS-relay, all channels isolated, balanced input
Time Scale 1 Second to 24 Hour /Division
Trigger Function Action:
>> Start or Stop Capturing Data by the Trigger
Source:
>> Start: Off, Input Signal, Alarm, External, Clock, Week or Time
>> Stop: Off, Input Signal, Alarm, External, Clock, Week or Time 
Combination:
>> OR or AND Condition at Level of Signal or Edge of Signal
Condition:
>> Analog: Rising, Falling, Window-in, Window-out
>> Pulse: Rising, Falling, Window-in, Window-out
>> Logic: Rising or Falling
Alarm Function Detection Method:
>> Level or Edge of Signal
Condition:
>> Analog: Rising, Falling, Windows-in, Windows-out
>> Pulse: Risiong, Falling, Windows-in, Windows-out 
>> Logic: Rising, Falling 
Alarm Output:
>> 4 Channels, Output Type: Open Collector (Pull-up Resistor 10 kΩ)
Pulse Input Accumulating Count Mode:
>> Number of Pulses from the Start of Measurement
>> Range: 50, 500, 5k, 50k, 5 M, 50 M, 500 M Counts/FS
Instant Count Mode:
>> Counting the Number of Pulses per Sampling Interval
>> Range: 50, 500, 5k, 50k, 5 M, 50 M, 500 M Counts/FS
Rotation Count (RPM) Mode:
>> Counting the Number of Pulses per second then Convert to RPM 
>> Range: 50, 500, 5k, 50k, 5 M, 50 M, 500 M Counts/FS
Maximum Input Pulse Rate:
>> 50 k pulses/sec or 50k Counts per Sampling Interval
>> 16 Bits Counter is Used
Display Size: 4.3" TFT Color LCD (480 x 240 pixels)
Formats: Waveform + Digital, Waveform Only, Calculation + Digital, Expanded Digital
A/D Converter ΣΔ Type; 16 Bits (Effective Resolution: 1/40,000 of Full Range)
Calculation Function Between Channels: Addition, Subtraction, Multiplication and Division for Analog Inputs
Statistical: Select 2 Calculations from Ave, Peak, Max, Min, RMS
Search Function Search for Analog Signal Levels, Values of Logic, Pulse or Alarm Points in Captured Data
Interface to PC USB (Full Speed)
Storage Devices Built-in Flash Memory (2 GB)
USB Memory Device
Data Saving Function Captured Data: Direct Saving of Data into Flash Memory or USB Memory Device
Others: Setting Conditions, Screen Copy
Ring Capturing Mode Function: ON/OFF 
Number of Capturing Point: 1,000 to 2,000,000
(Size of the Capture Data Will Be Limited to 1/3 of Available Memory)
USB Memory Device Function USB Memory Emulation Mode
(Transfer or Delete the file in Built-in Memory)
Engineering Scale Function Set Based on the Reference Point of the Scaled Output and Input Signal for Each Channel
Voltage Measurement: 4 Points Needed to Scale the Output
Temp Measurement: 2 Points Needed to Scale the Output
Withstand Voltage Between Channels: 350V p-p (1 Minute) 
Between Channel / GND: 350 V p-p (1 Minute)
Maximum Input Voltage Between ± Terminals: 60V p-p
Between Channels: 60V p-p
Between Channel / GND: 60V p-p
Operating Environment Temperature: 0 to 45°C
Humidity: 5 to 85% RH (Non-condensing)
Power Source AC Adapter: 100 to 240 Volts AC, 50/60 Hz (Included)
DC Input: (8.5 to 24 Volts DC; Max. 26.4 Volts)
Battery Pack: (Part #B-517 - Optional)
Power Consumption 29 VA or lower (Operating w/ AC Adapter, Displaying LCD)
OS Compatibility Windows XP, Vista and 7 (32 and 64 Bit Editions)
Dimensions 7.63" x 4.63" x 1.65"
Weight 520g (Excluding AC Adapter and Battery)


GL220 Midi Data Logger GL220 Midi Data Logger
>> Accepts Voltage, Temp, Humidity, Pulse and Logic Inputs
>> 10 Isolated Channels with 16-bit ADC resolution
>> 2GB Internal Data Storage and External USB Memory Drive
>> Includes Software, AC Adapter and User Manual
Part #: GL220
Standard NIST DC Voltage Calibration Service Standard NIST DC Voltage Calibration Service
>> 1 Point (per Channel) Offset Calibration
>> Traceable to NIST
>> Certificate Supplied
>> Note: 3 to 5 Day Lead Time for All Calibration Orders


Part #: CAL-NIST-DCVOLT

Optional Sensors for GL220 Midi Logger

Graphtec Humidity Sensor Graphtec Humidity Sensor
>> Temperature Range: -25°C to 80°C
>> Humidity Range: 0 to 100% RH
>> RH Accuracy: ±3% RH (5 to 98%RH at 25°C)
>> Response Time: 15 Seconds (90% Response Time When Membrane Filter Installed
>> Cable Length: 3 Meters
Part #: B-530
Welded Tip Teflon Thermocouple w/ 72" Bare Wire Leads Welded Tip Teflon Thermocouple w/ 72" Bare Wire Leads
>> Operating Range: -75°C to 250°C
>> Leads: 72" Teflon Insulated Twisted Pair Bare Wire Leads
>> Available in Type J, K, T and N
Quantity Price Each
1 - 9  
10 - 25  
26+  
Welded Tip Teflon Thermocouple w/ 72" Bare Wire Leads Welded Tip Teflon Thermocouple w/ 180" Bare Wire Leads
>> Operating Range: -75°C to 250°C
>> Leads: 180" Teflon Insulated Twisted Pair Bare Wire Leads
>> Available in Type J, K, T and N
Quantity Price Each
1 - 9  
10 - 25  
26+  

Optional Accessories for GL220 Midi Logger

Logic Alarm Cable Logic Alarm Cable
>> (4) Logic Inputs
>> (4) Alarm Outputs
>> Cable Length: 2 Meters
Part #: B-513
DC Drive Cable DC Drive Cable
>> 2 Meter Cable
Part #: B-514
Graphtec Battery Pack Graphtec Battery Pack
>> Capacity: 7.2 Volts/ 2200 mAh
>> Battery Type: Lithium Secondary Battery
>> Running Time: 2.5 Hours to 9.0 Hours
>> Charging Method: Mount in the Main Unit
>> Charging Time: 4 to 8 Hours
>> Operation Environment: 15°C to 40°C
Part #: B-517
Replacement AC Adapter Replacement AC Adapter
>> Compatible with GL220 and GL820
Part #: 682124530
Replacement AC Adapter Yellow Xtreme Protective Case
>> Yellow Waterproof, Crushproof Case
>> Inside Dimension: 11.93" x 9.02" x 4.02"
>> Outside Dimension: 12.81" x 10.36" x 4.64"
>> Conforms to MIL-STD-810F Transit
>> Includes Customizable Foam Inserts
Part #: T6000.2
Black Xtreme Protective Case Black Xtreme Protective Case
>> Black Waterproof, Crushproof Case
>> Inside Dimension: 11.93" x 9.02" x 4.02"
>> Outside Dimension: 12.81" x 10.36" x 4.64"
>> Conforms to MIL-STD-810F Transit
>> Includes Customizable Foam Inserts
Part #: T6000.3

GL220 Data Logger Documentation

GL220 Quick Start Guide
GL220 Software Controller Manual
GL220 User Manual

Application Notes

Understanding the Differences Between State, Event and Pulse Datalogging