Error
  • JUser: :_load: Unable to load user with ID: 42

AEMC 4-Channel Event Data Logger

>> 4 Input Channels for Event Recording
>> Compatible with Dry Contact Closures, 0 to 3 Volts DC, 0 to 5 Volts DC Sensors
>> 8 Every Second to 24 Hour Sampling Interval
>> Powered by Replaceable AA Alkaline Batteries
>> 50,000 Event Samples Stored in Non-Volatile Memory
>> 5 LED Indicators Display Logger Status
>> Includes Batteries, USB Cable and DataView Software for Real-Time Waveform Display, Analysis and Report Generation
>> Requires a Dry Contact Closure or DC Voltage Sensors

Required with Current Simple Logger®
>> Dry Contact Closures or DC Voltage Sensors

NOTE: Large Quantity Discounts Are Available!

Event Simple Logger® Specifications

Number of Channels 4 Channels
Input Connection (1) 8 Position Removable Screw Type Terminal Block
Voltage Range 0 to 5 Volts DC or Contact Closure
Sampling Rate 125 mS to 1 Day (User-Selectable)
Storage Rate Event Triggered
Storage Modes Event Logging
Recording Length 15 Minutes to 8 Weeks, Programmable using DataView
Recording Length 15 Minutes to 8 Weeks
Programmable Using DataView Software
Data Storage Capacity 50,000 Events
(Stored in Non-Volatile Memory, Retained If Battery is Low or Removed)
Communication USB 2.0 Optically Isolated
Power Source (2) 1.5 Volt AA-cell Alkaline Batteries
Battery Life 100 Hours to > 45 Days
(Dependent on Sample Rate and Recording Length)
Operating Range Temperature: 14°F to 122°F (-10°C to 50°C)
Storage Range Temperature: -4°F to 140°F (-20°C to 60°C)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
Standards Compliance EN61010-1; CAT III
Software DataView Software (Included)
OS Compatibility Windows XP, Vista and 7 (32-bit and 64-bit)
Dimensions 4.94" x 2.75" x 1.28" (125mm x 70mm x 32mm)
Weight 6.4 oz (181 grams)


4-Channel Event Data Logger 4-Channel Event Data Logger
>> 4 Input Channels
>> Records Up to 8 Samples per Second
>> Stores 50,000 Events in Non-Volatile Memory
>> Includes Batteries, USB Cable and DataView Software
>> Requires Contact Closures or DC Voltage Sensors
Part #: L404
Optional Accessories
AA Lithium Batteries AA Lithium Batteries
>> 4 Pack
Quantity Price Each
1 - 4  
5+  
Part #: HWSB-LI

4-Channel Event Simple Logger® Applications

  • Determine Machinery Run/Down Times
  • Determine Event Sequencing
  • Count Events and Records
  • Record Event Duration
  • Machine Load Monitoring