>> Data Uploaded and Viewed in your Internet Browser at HOBOLink.com
>> Electronics Housed Within a Rugged Double-Weatherproof, Tamper Proof Enclosure
>> Attach up to 15 Plug-and-Play Smart Sensors with Easy Set-up and Instructions
>> 3 to 5 Year Life with User-Replaceable Rechargeable Battery
>> 1 Second to 18 Hour Sampling Rate
>> AC Power Adaptor or Solar Panels Required External Power Option
>> Includes Alarm Output Relay (Activated, Deactived or Pulsed) On User-Defined Sensor Alarms
The U30 WiFi System Requires:
>> U30 Base Unit
>> Power Adapter or Solar Panels
>> Compatible Smart Sensors (Minimum 1)
>> Data Plan for Uploading Readings to Server
>> HOBOWare Pro Software
All U30s are Built to Order - 7 Day Lead Time is Required.
U30 WiFi Communications Data Logger Specifications
Data Channels | Max. 15 Channels (Some Smart Sensors use more than 1 Channel) |
Data Storage Capacity | 512K Maximum Storage in Non-volatile Memory (Number of Samples Dependant on External Sensors) |
Sampling Rate | 1 Second to 18 Hours (User-Specified) |
Smart Sensor Compatiblility | Compatible with Onset Smart Sensors, Except S-BPA, S-TMA and S-THA |
Logging Modes | Immediate, Timed Delay, or Push-Button Start Options |
Memory Modes | Stop When Full; Wrap When Full |
Sensor Inputs | 5 Standard - Option to Expand to 10 |
Alarm Output Relay | Activated, Deactivated or Pulsed on User-Defined Sensor Alarms (Relay Configured as Normally Open or Normally Closed - Rated for 30 Volts and 1 Amp Max.) |
Time Accuracy | 0 to 2 Seconds for first data point and ±5 Seconds per Week at 25°C (77°F) |
Communications | WiFi or Full Speed USB via USB mini-B Connector |
Expansion Slot | One Expansion Slot (Factory-Installed) |
Enclosure / Materials | Outer Enclosure: Polycarbonate/PBT Blend with Stainless Steel Hinge Pins, Brass Inserts Inner Enclosure: Polycarbonate with Brass Inserts U-Bolts: Steel with Zinc Dichtomate Finish Gaskets: Silicone Rubber Cable Entry Channel: EPDM Rubber Cable Entry Bars: Alum. w/ ABS Plastic Thumb Screws |
Enclosure Access | Hinged Door Secured by 2 Latches with Eyelets for Securing with User-Supplied Padlocks |
Mounting | 3.8 cm (1.5") Mast or Wall Mount |
Sensor Network Cable Length | 100 Meters (328 ft) Maximum |
Operating Range | Temperature: -20°C to 40°C (-4°F to 104°F) |
LED Status Lights | Up to 7 (dependant on Options) for Basic Diagnosis |
Battery | 4 Volt, 10AHr, Rechargeable Sealed Lead-Acid |
Battery Life | Rechargeable Service Life: 3 - 5 Years Typical Use (Dependant Upon Environment and Operating Range) |
External Power | Required with 4 Options to Choose from: AC-U30 Power Adapter Solar-1.2W Solar-3W Solar-6W |
WiFi | Network Standards: IEEE 802.11b; IEEE 802.11g (NOTE: Pre-N Routers are Preliminary and Should not be Used with the U30 Wi-Fi Remote Monitoring System at this time.) Frequency Range: 2.412GHz to 2.484 GHz Antenna Connector: 1, No Diversity Supported Data Rates: 1, 2, 5.5, 11 Mbps (802.11b); 6, 9, 12, 18, 24, 36, 48, 54 Mbps (802.11g) Radio: Number of Selectable sub-channels, Up to 14 Channels Profiles Available will include USA, France, Japan, Spain, Canada and Other Multiple Countries. Radio Modulations: OFDM, DSSS, DBPSK, DQPSK, CCK, 16QAM, 64QAM Radio Antenna Connector: 1 Security: WEP 64/128, WPA - PSK, TKIP, AES End to End Encryption Max. Receive Level: -10 dBm (with PER < 8%) Receiver Sensitivity: -72dBm for 54Mbps; -87dBm for 11Mbps; -89dBm for 5.5Mbps; -90dBm for 2.0Mbps; -92 dBm for 1.0Mbps Antenna Type: Internal Antenna with Reverse SMA Connector |
Alarm Notification Latency | Logging Interval Plus 2 to 4 Minutes (Typical) (Not Responsible for Failed Connections or Undelivered Email/Text Messages) |
Standards Compliance | CE, NEMA 6 Weatherproof Enclosure (Proper Installation of Cable Channel System) |
Weight | 2 kg (4 lbs 10 oz) |
Dimensions | 17.8cm x 11.7cm x 19.3cm (7.0" x 4.6" x 7.60") |
Optional Analog Sensor Port Specifications | |
Input Channels | (2) Single-Ended |
Field Wiring | 2- or 3-wire via Screw Terminals on Detachable Connector |
Input Range | User-Configurable: 0 to 20 mA DC, 0 to 20 VDC (Suitable for 2.5, 5, and 10 V Sensors) |
Input Voltage | 0 to 24 VDC |
Input Current | 0 to 24 mA DC |
Current Source Impedance | Minimum: > 20 KΩ |
Accuracy | ±0.25% of FSR from 50mV to FSV |
Excitation Power | Switched 12 VDC, up to 50 mA; User-Selectable Warm-up from 5 msec to 2 Minutes |
ADC Resolution | 12 Bits |
Part # | U30-WIF-000-05-S100 |
Base Price | |
Analog Sensor Port Options | |
Note: Choosing 2 analog inputs provides 2 analog inputs and sensor power; and is user-configured for either 0-20 mA or 0-20V. |
|
Smart Sensor Input Options | |
Note: 5 smart sensor inputs includes weatherproof inlets for up to 5 sensor cables. 10 smart sensors inputs includes weatherproof inlets for up to 11 sensor cables, and 1 oversized cable (0.25") |
|
Note: A 10 AHr Rechargeable Battery is Included. |
Standard NIST DC Voltage Calibration Service >> 1 Point (per Channel) Offset Calibration
>> Traceable to NIST >> Certificate Supplied >> Note: 3 to 5 Day Lead Time for All Calibration Orders |
|
|
Standard NIST 4-20mA Calibration Service >> 1 Point Offset Calibration
>> Traceable to NIST >> Certificate Supplied >> Note: 3 to 5 Day Lead Time for All Calibration Orders |
Part #: CAL-NIST-420MA |
Documentation
U30 Remote Communications Quick Start Guide
U30 Remote Communications User Manual
U30 Battery Replacement Guide
HOBOLink Quick Start Guide
HOBOLink User Manual
Application Notes
Understanding the Differences Between State, Event and Pulse Datalogging. (.pdf 300KB)